Code Requirements:
u The electrical installation must conform to the most current version of the National
Electrical Code, NFPA No. 70, and all applicable local and state codes.
u National Electrical Code, article 680; Swimming Pools, Fountains, and Similar Installations, shall
apply.
u National Electrical Code, article 440, Air-Conditioning and Refrigeration Equipment, shall apply.
Reference Equipment Data Plate:
u All TropiCal heat pumps have their data plates located on the left, exterior, side panel.
Refer to equipment data plate for unit-specific electrical power and over-current protection
requirements. Based on data plate information; size wiring, devices, and over-current
protection per applicable codes and standards.
u See drawing below for data plate details specific to Electrical Installation Requirements. The
numbered areas represented below will contain the necessary information required in sizing
electrical service and over current protection devices.