Aquacal AT120 Heat Pump User Manual


 
20
WATER LEAKING OUT OF THE HEAT PUMP
(Is it a leak or just condensation from normal operation? Here’s how to find out).
o Shut off your heat pump, leaving the pool pump running. In a couple of hours
there should be a marked reduction in the amount of water around the bottom of
the heat pump.
o Or, as an alternate method to check for a water leak, you can test the water
draining out the base for the presence of the sanitizer you are using in your pool
or spa. Use your water test kit, or a test strip, to check a sample of the water for
chlorine or bromine. If the sample tests positive for sanitizer, call AquaCal for
service at: 800-786-7751. If the test is negative, the water is probably harmless
condensate.
NOTE:
I
F YOU ARE USING AN IONIZER OR OZONE GENERATOR TO PRODUCE SANITIZER
,
THIS
TEST
METHOD WILL NOT BE EFFECTIVE
.
WHAT WE NEED TO KNOW WHEN YOU CALL US