LOCATION
For Wall Mount:
• Locate on an inside wall of living area approximately 5’ above
the floor.
• Do not locate control in the direct path of drafts from open
doors and windows.
• Do not install where operation might be affected by lamps,
sunlight, fireplace, registers, radiators, concealed air ducts and
pipes, or room occupants.
• The basic rules for location of thermostats also apply to
humidifier controls.
For Duct Mount:
Locate on the furnace return air plenum or duct, at least 6”
upstream of the humidifier, humidifier bypass ductwork (if
applicable) or fresh air intake ductwork (if applicable).
Control can be mounted on wall in living space or on return duct.
GENERAL INSTRUCTIONS
• Do not mount the Humidifier Control on counter flow furnace.
Furnace malfunction will result in improper humidifier
operation.
• Be sure the Humidifier Control is installed on a 24 VAC circuit
only.
• Make sure no bare wires are exposed or insulation damaged.
• Make sure all splices are mechanically and electrically secure.
• To remove dirt or other foreign matter from the nylon ribbon
and control interior, dust lightly with a fine soft brush.