2.5 Mounting the inner door
Mode of operation: (see figur 8).
1. Place the clips in the position on the
inner door so the door can fullty stick
into the opening.
2. Lift the door up and rotate it over the
burner into position.
3. Pull the inner door against the inside
of the skirt ring.
4. Rotate the clips into postion with a
tool.
Figur 8 Removing and replacing the
inner door.
2.6 Temperature regulation
The appliance is under water supply
pressure (maximum 8 bar). The amount
of cold water that is added is equal to
the amount of hot water used. The gas
control block automatically regulates the
gas supply. The main burner will ignite
as soon as a reduction in water
temperature is sended by the
thermostat. The main burner will shut
down as soon as the preset
temperature is achieved.
At high water temperatures there is
more scale buildup in the appliance. It is
for this reason that it is recommended to
place the temperature control knob in
position of
60 °C as the accumulation of scale will
be reduced.
1) Burner bracket
2) Inner door
3) Clip
4) Mainburner
5) Skirt ring
6) Outer casting
7) Base tray