Annovi Reverberi Plunger Pumps Water Pump User Manual


 
Plunger Pumps
Operating Instructions and Parts Manual RK Series Pumps
First Choice When Quality Matters
NORTH
AMERICA
Symptom Possible Cause(s) Corrective Action
Low pressure (cont.) 3 Air leak in inlet plumbing 3 Disassemble, reseal and reas-
semble
4 Relief valve stuck, partially
plugged or improperly
adjusted valve seat worn
4 Clean and adjust relief valve;
check for worn or dirty valve
seats
5 Worn packing. Abrasive
in pumped in cavitation.
Inadequate water
5 Install proper filter suction at
inlet manifold must be limited to
lifting less than 20 feet of water
or 8.5 psi vacuum
6 Worn inlet, discharge valve
blocked or dirty
6 Replace inlet and discharge valve
Pump runs extremely
rough, pressure very
low
1 Inlet restrictions and/or air
leaks.
1 Clean out foreign material
2 Stuck inlet or discharge
valve
2 Replace worn valves
Water leakage from
under manifold
Worn packing or cracked
plunger
Install new packing or plunger
Slight leak, oil leak-
ing in the area of
crankshaft
1 Worn crankshaft seal or
improperly installed oil seal
o-ring
1 Remove oil seal retainer and
replace damaged 0-ring and/or
seals
2 Bad bearing 2 Replace bearing
Excessive play in the
end of the crankshaft
pulley
Worn main bearing from
excessive tension on drive
belt
Replace crankcase bearing and/or
tension drive belt
Water in crankcase 1 Humid air condensing into
water inside the crankcase
1 Change oil intervals
2 Worn packing and/or
cracked plunger
2 Replace packing. Replace
plunger
Loud knocking noise
in pump
1 Cavitation or sucking air 1 Check water supply is turned on
2 Pulley loose on crankshaft 2 Check key and tighten set screw
3 Broken or worn bearing 3 Replace bearing
Troubleshooting (cont.)