Amtrol WELL-X-TROL Water Heater User Manual


 
In-Line Models
Stand Models
WELL-X-TROL Professional
residential
models
Underground Models
Dimensions Total Max. System Drawdown Shipping
Model
Diameter Height Volume Accept. 20/40 30/50 40/60 Wt. (Vol.)
No.
(ins) (ins) (gals) Factor (gals) (gals) (gals) lbs (cu ft)
WX-101 8 12 5/8 2.0 0.45 .8 .7 .6 5 (0.6)
WX-102 11 15 4.4 0.55 1.8 1.5 1.3 9 (1.2)
WX-103 11 22 1/4 7.6 0.42 3.1 2.6 2.2 15 (1.8)
WX-104 15 3/8 17 3/4 10.3 1.00 4.1 3.5 3.0 20 (2.6)
WX-200 15 3/8 22 14.0 0.81 5.6 4.8 4.1 22 (3.3)
Pr
echarge Pressure for WX-101
& WX-102 is 20 PSIG and Sys. Conn. is 3/4" NPTM.
Precharge Pressure for WX-103 is 30 PSIG and Sys. Conn. is 3/4" NPTM.
Pr
echarge Pressure for WX-104 and WX-200 is 30 PSIG and Sys. Conn. is 1" NPTM.
Maximum Working Pressure is 125 PSIG and Maximum Working Temperature is 200° F.
WX-101 and WX-102 models available with Ultra TUF-KOTE
TM
exterior coating option.
Dimensions Total Max. System Drawdown Shipping
Model Diameter Height Volume Accept. 20/40 30/50 40/60 Wt. (Vol.)
No. (ins) (ins) (gals) Factor (gals) (gals) (gals) lbs (cu ft)
WX-104-S 15 3/8 19 1/4 10.3 1.00 4.1 3.5 3.0 23
WX-201 15 3/8 23 7/8 14.0 0.81 5.6 4.8 4.1 25
WX-202 15 3/8 31 5/8 20.0 0.57 8.0 6.8 5.9 33
WX-202XL 15 3/8 38 1/4 26.0 0.44 10.5 8.8 7.6 36
WX-203 15 3/8 46 1/2 32.0 0.35 —- 10.9 9.4 43
WX-205 22 29 5/8 34.0 1.00 13.7 11.6 10.0 61
WX-250 22 36 44.0 0.77 17.7 15.0 12.9 69
WX-251 22 46 3/4 62.0 0.55 24.9 21.1 18.2 92
WX-255
22
56 3/8 81.0 0.41 32.6 27.5 23.8 103
WX-252 22 62 1/4 86.0 0.39 34.6 29.2 25.3 114
WX-302
26
47 1/4 86.0 0.54 34.6 29.2 25.3 123
WX-350 26 61 7/8 119.0 0.39 47.8 40.5 35 166
Pr
echarge Pressure for WX-104-S thru WX-203 is 30 PSIG and Sys. Conn. is 1" NPTF.
Pr
echar
ge Pr
essure for WX-205 thru WX-350 is 38 PSIG and Sys. Conn. is 1 1/4" NPTF.
Maximum Working Temperature is 200° F. Maximum Working Pressure for all models except WX-252 is 125 PSIG.
Maximum Working Pressure for WX-252 is100 PSIG.
All models available with
Ultra TUF-KOTE
TM
except WX-104-S, WX-201, and WX-252.
All models except, WX-104S, WX-201, WX-252 are available with Pro-Access.
Dimensions Total Max. System Drawdown Shipping
Model
Diameter
Height
V
olume
Accept.
20/40
30/50
40/60 Wt. (Vol.)
No.
(ins) (ins) (gals) Factor (gals) (gals) (gals) lbs (cu ft)
WX-200-UG 15 3/8 22 14.0 0.81 5.6 4.8 4.1 22
WX-202-UG 15 3/8 30 20.0 0.57 8.0 6.8 5.9 30 (4.9)
WX-250-UG 22 33 3/8 44.0 0.77 17.7 15.0 13.0 60 (9.8)
WX-251-UG
22
44 1/8
62.0
0.55
24.9
21.1
15.3 83 (13.9)
Precharge Pressure for WX-202-UG is 30 PSIG and Sys. Conn. is 1" NPTF Coupling.
Precharge Pressure for WX-205-UG and WX-251-UG is 38 PSIG and Sys. Conn. is 1 1/4" NPTF Coupling.
Maximum Working Pressure is 125 PSIG and Maximum Working Temperature is 200° F.