-3-
3. REQUIRED COMPONENTS AND
ACCESSORIES CHECKLIST
SHUTOFF VACUUM RELIEF THERMAL EXPANSION
MODEL CIRCULATOR ZONE VALVE* VALVE BREAKER VALVE TANK DRAIN
Residential = 5GPM *If Circulator not used Required
WH SERIES Commercial = 10GPM 3/4” Full Port 4 1 Included (See Therm-X-Trol
®
Included
Except “P” Models or 1” STD Sizing Guide)
5GPM *If Circulator not used Required
TD SERIES Except “P” Models 3/4” Full Port 4 1 Included (See Therm-X-Trol
®
Included
or 1” STD Sizing Guide)
Required
RTR SERIES Included N/A 4 1 Included (See Therm-X-Trol
®
Included
Sizing Guide)
Residential = 5GPM *If Circulator not used Required
WHS SERIES Commercial = 10GPM 3/4” Full Port 4 1 Included (See Therm-X-Trol
®
Included
Except “P” Models or 1” STD Sizing Guide)
ALL INSTALLATIONS REQUIRE TEFLON
®
SEALING TAPE OR PIPE DOPE FOR THREADED JOINTS.
SEE HEAT EXCHANGER PRESSURE DROP CHART TO DETERMINE PUMP HEAD REQUIREMENTS.
Use this chart to select the proper circulator for your BOILERMATE
®
.
If a steel hydropneumatic tank is in place, AMTROL
®
recommends replacing it with a
properly sized EXTROL
®
or Radiant EXTROL
®
expansion tank. Otherwise, significant
heat transfer problems can occur by causing air to be trapped in the heat exchanger. If the boiler system has
an EXTROL
®
or Radiant EXTROL
®
expansion tank and the boiler temperatures are being changed, resize the
EXTROL
®
or Radiant EXTROL
®
expansion tank.