American Water Heater NRGSS01110 Water Heater User Manual


 
Order Entry and Sales
500 Princeton Road (FEDEX, UPS)
Johnson City, TN 37601-2030
P.O. Box 4808 (Mailing)
Johnson City, TN 37602-4808
(800) 937-1037
FAX (800) 581-7224
No part of this work may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or by any information storage retrieval system, without permission in writing from American Water Heaters.
Distributed By:
Warranty and Service
500 Princeton Road (FEDEX, UPS)
Johnson City, TN 37601-2030
P.O. Box 1597 (Mailing)
Johnson City, TN 37605-1597
(800) 456-9805
FAX (800) 999-5210
Residential Gas
High Eciency Power Vent
Residential gas water heater(s) shall be models ____________ as manufactured by American Water Heaters, or an approved equal, and shall have a ______ -year tank
warranty and a ______ -year parts warranty, when installed in a residential application. Heater(s) shall have a storage capacity of ______ gallons and shall have a rated
input of __________ BTUs, and shall be designed, tested and listed with CSA International in accordance with the latest edition of ANSI Z21.10.1 - CSA4.1 standard.
Heaters shall meet or exceed the Federal Energy Eciency Standards eective January 20, 2004, according to the National Appliance Energy Conservation Act (NAECA) of
1992. The interior of the storage tank shall be lined with a Fused Ceramic Shield lining, fused to the tank at 1600° F, forming a corrosion-resistant lining; polymer linings
are not acceptable. Each tank shall be furnished with an internal powered anode for cathodic protection. The unit must be equipped with a combination gas control
thermostat and non-reset type ECO. A corrosion-resistant drain valve shall be provided on the front of each unit. The tank shall be totally encased in a steel jacket, painted
and insulated with a non-CFC foam to reduce standby heat loss. The tank must be design certied for 300 PSI test pressure and 150 working pressure.
Residential Gas Water Heater Specication
NRGSS01110
Inlet and outlet connections: 3/4” male
Circulation loop connections: 3/4” female
90% THERMAL EFFICIENCY POWER VENT
CODES AND STANDARDS
Design-certified by UL (Underwriters Laboratories) according to ANSI Z21.10.3 - CSA 4.3 Standards
Meets or exceeds the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition ASHRAE/IESNA 90.1
MODEL
NUMBER
BTU
INPUT
PER
HOUR
GALLONS
OR
LITRES
FIRST HOUR
DELIVERY
GALLONS
OR
LITRES
RECOVERY
GALLONS
OR
LITRES
90°F/50°C RISE
DIMENSIONS
INCHES/CENTIMETERS SHIPPING
WEIGHT
LBS/KG
A B C D E F G H J K
VG6250T76NV 76,000
50 127 92 70-5/8 68-1/4 52 21 9-1/8 12 22 8 15-3/4 27 210
189 481 92 179 173 132 53 23 30 56 20 40 68 95
(B)
* INSTALL IN ACCORDANCE WITH LOCAL CODES
TOP VIEW
ANODE
(J)
(H)
(K)
HOT COLD
(A)
(C)
(G)
(F)
(D)
(E)
DIAMETER
SIDE INLET
THERMOSTAT
DRAIN
VALVE
T & P VALVE
SIDE OUTLET
OUTLET
(L)
(L)
INLET
FRONT VIEW
NRGSS01110 Res Gas Spec.indd 2 7/8/10 11:08 AM