American Water Heater NRESS00408 Water Heater User Manual


 
No part of this work may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or by any information storage retrieval system, without permission in writing from American Water Heaters.
Distributed By:
Order Entry and Sales
500 Princeton Road (FEDEX, UPS)
Johnson City, TN 37601-2030
P.O. Box 4808 (Mailing)
Johnson City, TN 37602-4808
(800) 937-1037
FAX (800) 581-7224
Warranty and Service
500 Princeton Road (FEDEX, UPS)
Johnson City, TN 37601-2030
P.O. Box 1597 (Mailing)
Johnson City, TN 37605-1597
(800) 999-9515
FAX (800) 999-5210
Residential Electric Lowboy
NRESS00408
ACCESS
PANEL
DRAIN
VALVE
ACCESS
PANEL
T&P VALVE
ANODE
JUNCTION
BOX
T&P VALVE
E61-19L-045DV 19 20.7 N/A 16 31-1/4 24-1/4 60
E61-40L-045DV*** 38 20.7 0.92 22 31-5/8 24-1/4 113
E61-50L-045DV*** 46.5 20.7 0.91 24 31-5/8 24-1/4 133
E62-30L-045DV 28 20.7 0.93 22 29-1/2 22-1/2 84
E62-40L-045DV 38 20.7 0.92 24 31-5/8 24-1/4 113
E62-50L-045DV 46.5 20.7 0.91 26 31-5/8 24-1/4 133
HEIGHT TO HEIGHT TO
GPH JACKET TOP OF SIDE T&P APPROX.
GALLON RECOVERY DIAMETER HEATER VALVE SHIPPING
MODEL NUMBER CAPACITY 90° RISE EF A B C WEIGHT
To order single element substitute “S” for “D” in model number. Delete “V” from model number for top T&P option, T&P opening on top of the heater with the valve shipped in
the box for  eld installation. All models include internal heat traps. Dimensions and speci cations subject to change without notice in accordance with our policy of continuous
product improvement. Dimensions on all charts shown in inches. All models are wired for non-simultaneous element operation. 3/4” water connection located on top. Top water
connections are on 8” centers. ***Supplied with insulating jacket.
Speci cation
Residential electric water heater(s) shall be Lowboy model ____________ as manufactured by American Water Heaters, or an approved equal, and shall have a ______
-year tank warranty and a ______ -year parts warranty, when installed in a residential application. Heater(s) shall have a storage capacity of ______ gallons and shall have
a rated input of __________ KW at __________ Volts, single phase, 60 cycle AC, and shall be designed, tested and listed in accordance with Underwriter’s Laboratories
standard UL 174. Heaters shall meet or exceed the requirements of the Federal “National Appliance Energy Conservation Act of 1987” and shall comply with ASHRAE
Standard 90.1-1999. The interior of the storage tank shall be lined with a Fused Ceramic Shield lining, fused to the tank at 1600°F, forming a corrosion-resistant lining;
polymer linings are not acceptable. Each tank shall be furnished with an internal anode for cathodic protection. The unit must be equipped with a built-in electrical
junction box. Electrical heating elements shall be screw-in, direct immersion, resistance type. Element operation shall be controlled by a thermostat for each element.
A high temperature cut-o shall be supplied as an integral part of the heater. Element access panels shall be provided on the front of the heater for each element. A
corrosion-resistant drain valve shall be provided on the front of each unit. The tank shall be totally encased in a metal jacket and insulated with a non-CFC foam to reduce
standby heat loss. The tank must be design certi ed for 300 PSI test pressure and 150 PSI working pressure.
American Spec Sheets 2008 new te36 36American Spec Sheets 2008 new te36 36 2/27/08 2:20:22 PM2/27/08 2:20:22 PM