American Water Heater BCL3 95T199 6NOX Water Heater User Manual


 
19
TABLE 7. TECHNICAL DATA VENTING (Continued)
MODEL (A)BCL3 85T275 6NOX
Input: 275,000 Btu/hr Total Vent Height (Feet)
Vent Connector Size: 6 inches
6 8 10 15 20 30 50 100
Input Btu/hr
Rise
Vent Connector Diameter (Inches)

 8 8 7 7 6 6 6 6

 8 8 7 7 6 6 6 6

 7 7 7 7 6 6 6 6
Number of 275
Heaters
Combined Input in
Thousands of Btu/hr
Manifold and Common Vent Diameters (Inches)
2

10 9 9 8 8 8 7 7
3

12 12 12 10 9 9 8 8
4

14 14 14 12 12 10 9 9
MODEL
(A)BCL3 85T390 6NOX
Input: 390,000 Btu/hr
Total Vent Height (Feet)
Vent Connector Size: 6 inches
6 8 10 15 20 30 50 100
Input Btu/hr
Rise
Vent Connector Diameter (Inches)

 10 9 9 9 8 8 8 8

 9 9 9 8 8 8 8 8

 9 9 8 8 8 8 8 8
Number of 400 Heaters
Combined Input in
Thousands of Btu/hr
Manifold and Common Vent Diameters (Inches)
2

12 12 10 10 9 9 8 8
3

14 14 14 12 12 10 10 9
4

16 16 16 14 14 12 12 10