American Standard 7430.821 Plumbing Product User Manual


 
M968640 REV.1.1
5
To change direction of handle
rotation, proceed as follows:
Turn valve to OFF position.
Thread counter-clock wise
HANDLE BASE (1) to remove
HANDLE ASSEMBLY (2) from
ESCUTCHEON BASE (3).
Use a flat blade screw driver
to remove SPRING CLIP (4).
Lift STOP WASHER (5), turn 90˚
and replace.
Replace SPRING CLIP (4).
Reinstall HANDLE ASSEMBLY (2)
.
If spout drips, operate handles
several times from OFF to ON
position. Do not force - handles
turn only 90˚.
To change from swivel to fixed spout, proceed as follows:
Remove PLUG BUTTON (1) from back of spout. VIEW “A”
Remove SET SCREW (2) using screwdriver.
Install FIXING SET SCREW (3) using Hex Wrench supplied.
Align SPOUT (4) and tighten SET SCREW (3) to secure SPOUT (4).
Replace PLUG BUTTON (1).
SERVICE
CARE INSTRUCTIONS:
90˚
17
15
16
VALVE
13
CHECK DRAIN CONNECTIONS
TEST INSTALLED FITTING
With HANDLES (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3). First loosen aerator set screw with
HEX WRENCH (6) supplied. Pull out AERATOR (3) with
AERATOR KEY (7).
Operate both HANDLES (1) to flush water
lines thoroughly.
Replace AERATOR (3) and tighten set screw.
HOT
COLD
2
4
2
1
“P” TRAP
AERATOR
SET
SCREW
WASTE
OUTLET
3
Operate POP-UP KNOB (5) and fill Sink with water. Check
that DRAIN STOPPER (4) makes a good seal and retains
water in Sink. If STOPPER (4) does not seal properly, please
refer to “Troubleshooting Guide” in these instructions.
Release POP-UP KNOB (5) down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
7
6
5
14
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
1
1
1
1
2
5
3
4
2
VIEW "A"
CONVERT TO A FIXED SPOUT IF DESIRED.
SPOUT CAN BE FIXED OR SWIVEL.
3
VIEW "A"
4