American Standard 32-5037-01 Furnace User Manual


 
© 2004 American Standard Inc. All Rights Reserved 32-5037-01
User’s Information
To Start the Furnace
Lighting instructions.
Your oil furnace does not use a continuously burning pilot
flame. Therefore, manually lighting your furnace is not
required. Your furnace is equipped with an automatic spark
ignition system that automatically lights the burner each
time the thermostat signals the furnace to start.
WARNING
!
Do not attempt to manually light the furnace.
TO OPERATE THIS FURNACE:
1) Adjust the room thermostat to the lowest setpoint and set
the operating mode, if equipped, to “OFF”.
2) Turn off all electric power to the furnace at the disconnect-
ing switch.
3) Turn the manual oil shutoff valve to the open or “ON”
position.
4) This furnace is equipped with an electronic ignition
system that automatically lights the burner. DO NOT
try to light the burner by hand.
5) Turn on the electric power to the furnace at the disconnect-
ing switch.
6) Adjust the room thermostat to the desired setpoint and set
the operating mode, if equipped, to “HEAT”.
7) If the furnace will not operate, call a qualified heating
dealer for service.
WARNING
!
BODILY INJURY CAN RESULT FROM HIGH VOLTAGE
ELECTRICAL COMPONENTS, FAST MOVING FANS, AND
COMBUSTIBLE FUEL OIL. FOR PROTECTION FROM
THESE INHERENT HAZARDS DURING INSTALLATION
AND SERVICING, THE ELECTRICAL SUPPLY MUST BE
DISCONNECTED AND THE MAIN FUEL OIL VALVE MUST
BE TURNED OFF.
WHAT TO DO IN THE EVENT OF AN OIL LEAK:
• Do not try to operate this or any other nearby appliance.
• If present, close the manual oil shutoff valve on the fuel oil
supply line.
• Immediately call a qualified heating dealer for service.
• If you cannot reach a qualified heating dealer, call the fuel oil
supplier or the fire department.
NOTICE: A qualified heating dealer MUST service the
oil burner and inspect the heat exchanger in this
furnace at least once a year.
TO INTERRUPT (STOP) OPERATION OF THIS FURNACE:
1) Adjust the room thermostat to the lowest setpoint and set
the operating mode, if equipped, to “OFF”.
2) If service will be performed, turn off all electric power to
the furnace at the disconnecting switch.
3) Turn the manual oil shutoff valve to the closed or “OFF”
position.
Extended Shutdown
If the furnace will be shutdown for an extended period of
time:
1) Adjust the room thermostat to the lowest set point and set
the operating mode, if equipped, to “OFF”.
2) Open the disconnecting switch serving the furnace.
3) Close the manual oil shutoff valve.
CAUTION
!
If this is done during the cold weather months, provisions
must be taken to prevent freeze-up of all water pipes and
water receptacles.
4) To promote smooth startup and nuisance free operation,
fuel oil quality must be maintained at a high level. In
cases where biological contamination of the fuel oil tank
is evident or suspected, consider treating the fuel oil
with a biocide approved for fuel oil applications. In
addition, for non-low sulfur fuel oils, an antioxidant
additive may be beneficial in promoting fuel stability.
After adding any fuel oil treatment, completely fill the
oil tank to promote mixing of the additive with the fuel.
Whenever your house is to be vacant, arrange to have
someone inspect your house for proper temperature. If your
furnace should fail to operate, damage could result, such as
frozen water pipes.
WARNING
!
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Refer to
the installation instructions provided with the oil furnace
and this manual. For assistance or additional information
consult a qualified installer, service agency or the fuel oil
supplier.