Amcor UCHW-H09AF2 Air Conditioner User Manual


 
1
*
Selection of installation positions fo r indoor unit
*
*To be installed at the position w here the air delivered from the unit can reach every corner of
the room ;
*To avoid being affected by the outdoor air;
*To avoid blockage to the air inlet or outlet of the unit;
*To avoid too
much oil sm oke or steam ;
*To avoid possible generation, inflow , lingering or leakage of flam m able gases;
*To avoid high-frequency facilities (such as high frequency arc welders, etc.);
*To avoid the places w here acid solutions are frequently used;
*To avoid t
he places w here som e special sprayers (sulfides) are frequently used.
*Not to install a fire alarming device near the air outlet of the unit (during operation, the fire alarm
device might be erroneously triggered by the war
m air from the unit);
INSTALLATION & REPAIR GUIDE
Split Wall-M ounted Air C onditioner
Above 100m m (4")
Left side: 150m m (6")
and above
Right side: 150m m (6")
and above
Ceiling
Wall hanging plate
ground
2300m m (7'6")
and above
*
M ake sure of enough space for installation and maintenance.
*To take into consideration the operational convenience and safety in installation, it is recom m ended
to ensure enough space betw een the unit and the walls.
*
Height limits of indoor and outdoor units.
*Either the indoor unit or the outdoor unit can be higher, but the height difference must com ply the stated
requirem ents.
*Try to reduce the bending of the piping line as much as possible so as to avoid possible negative im pacts upon the
perf
orm ances of the units.
Indoor unit
outdoor
unit
5m (16'5")max.