Amcor 10KE-410 Air Conditioner User Manual


 
5
GB
Put the exhaust hose into the round side of the exhaust hose adapter (13) (fig. 1).
Put the wall/window adapter (14) onto the exhaust hose (fig. 2).
Connect the hose with the rectangular end to the air conditioner (fig. 4).
Using the foam.
Place the foam with the hole (11), if needed together with the foam extension (10),
in the window and close this as far as possible to refrain the warm air from re-
entering the room (fig. 5). Depending on how the window opens, horizontally
(fig. 3a) or vertically (fig. 3b).
Pass the hose through the opening in the foam (11).
Permanent hole in glass or wall.
Place the wall/window connector (14) in the hole with diameter 130 millimetre
(fig. 6). Connect the hose with the rectangular end to the air conditioner (fig. 4).
Use the cap (15) to close the opening when the air conditioner is not used.
Important
The flexible exhaust hose can be extended from 300 to 1500 mm for mounting.
This length has been designed especially according to the specifications of the air
conditioner. Do not use an extension or exchange for a different hose as that may
lead to malfunctioning.
The exhaust air must flow freely, any blockage can lead to overheating of the air
conditioner. Take care to prevent any bow or bend in the exhaust hose.