Amana 5M11TB Air Conditioner User Manual


 
Electrical Requirements
Electrical Grounding Instructions
This appliance isequipped with a three-pro ng grounding plug
fer protection against possible shock hazards. Ifatwe-prong
wall receptacle is encountered, the customer is required to
contact a qualified electrician and have the two-prong wall
receptacle replaced with a properly grounded three-prong
wall receptacle in accordance with the National Electrical
Code.
Room air conditioners are designed tooperate according to
requirements on the nameplate and as shown in Table 1.
Fuse or circuit breaker ratings must be according to the fuse
instruction label and as shown in Table 1. Do not plug
models marked "Use on Single Outlet Circuit Only" into a
circuit with another appliance or light fixture.
i _i WARNING
To avoid death, personal injury or property
damage due to electrical shock, this unit
must be grounded. Do not under any
circumstances cut or remove the round
grounding prong from the plug. Do not use
a two-prong adapter.
WARNING
To avoid death, personal inju ry or property
damage due to electrical shock, do not use
an extension cord. Do not pinch the power
cord. Do not remove the warning tag from
the power cord.
Unit Plug Type Receptacle Circuit Rating, Voltage Rating
Required Breaker or On Unit Nameplate
Time
Delay Fuse
(_ 125V-15AMP 115V
NEMA No 5-15P NEMA No 5=15R
230/208V rated
250V-15AMP
at 12 amperes or less
NEMA No 6-15P NEMA No 6-15R
230/208V rated over
250V-20AMP 12 amperes but not more
than 16 ampf_res
NEMA No 6-20P NEMA No 6-20R
230/208V rated
250V=30AMP
at 24 amperes or Eess
NEMA No 6-30P NEMA No 6-30R
Safety Features
This room air conditioner is equipped with an electronic
control to improve comfort and ensure reliability.
Compressor Lockout
To extend the life of the compressor a three minute time
delay will occur when:
Electrical power is first supplied to the unit
The thermostat is turned down immediately after the
compressor stops running,
The Fan Control is quickly turned from FAN ONLY to
COOLING mode or vice versa.
Low Voltage Protection
This unit is equipped with "brownout" protection. In case
of an extreme brownout, the Amana control will interrupt
power to the unit to prevent compressor failure. When the
line voltage reaches at least 100 VAC, the control will re-
energize your unit.
Note: A compressor lockout will occur after the unit is re-
energized.
Table 1
,Digital Temperature Setting
- Temperature can be set from 60°F to 90°F in I°F
increments
,Digital Temperature Display
- Shows indoor room temperature in FAN ONLY
mode
- Shows desired temperature setting in other modes
,Computer Memory that Remembers
- The unit remembers the last settings used when
last turned on.
,TempAsure ®Thermostat
- Maintains set temperature within 1.5°F for maxi-
mum comfort
,Smart Cool
,Energy Saver with TempAsure ®air sampling
,Delay Timer
2