Alto-Shaam DX 865 Vacuum Cleaner User Manual


 
8
DX 845 W / DX 865 / DX 985 / TitanEnergy / TitanEnergy X
GB
READ THE OPERATING
INSTRUCTIONS AND
OBSERVE THE
ENCLOSED SAFETY
NOTES!
Dear Alto customer,
We thank you for the faith which
you have placed in Alto and are
sure that you have made the
right decision.
GENERAL
Your Alto high-pressure cleaner
has been developed specially for
professional use.
If you observe these operating
instructions and comply with the
notes given, your high-pressure
cleaner will help you in your
cleaning work for many years to
come.
Use only Alto products developed
for your high-pressure cleaner as
cleaning agents.
We observe time and again that
faults are due to the use of
unsuitable products.
The following table gives an
overview of the potential applica-
tions and of the corresponding
Alto cleaning agents.
0
0
6
19 32
45
2,0
1,0
3,0
4,0
%
5,0
Undiluted
1:1
1:2
1:5
1:10
1:20
Additivethrough-
put approx. l/h
Mixing ratio
Further highly effective cleaning and care
agents can be found in the catalogue "Alto
Cleaning and Care Agents".
Setting on the
metering valve
No.
81218
81227
Unsuitable cleaning
agents lead to poor
cleaning results and
cause damage to the
machine. Predilute the
concentrate as
instructed.
Alto AutoActive
Intensive acting concentrate
against dust, soot, greases,
oils and insect residues. For
delicate surfaces.
Alto Intensive
Multi-purpose concentrate
for heavy soiling on
engines, machine parts, in
workshops, on trucks and
on tarpaulins.
Pure or
pre-
diluted
1:10
1:10
pH
value in
1%
solution
approx.
9,5
9,1
DESCRIPTION (FIG. 1)
1 RotoFix high-pressure spray
lance with VarioPress trigger
gun
1)
2 Water connection
3 Steering roller with parking
brake
4 High-pressure connection
5 Cleaning agent tank
6 Mains cable storage point
7 Hose storage point
8 Spray lance storage clip
9 Exhaust pipe
10 Operating panel
11 Fuel tank
12 Pressure gauge
13 Temperature controller
14 Operation indicator light
15 Fuel shortage indicator
16 Scale alarm
1)
17 Operating mode switch
18 Cleaning agent metering
knob
BEFORE STARTING WORK
If the machine is to be operated
at fuel stations or in other
potentially hazardous areas, the
machine may only be employed
outside the hazard areas defined
in the "Technical Guidelines for
Inflammable Fluids" applicable at
the point of use due to the
potential explosion hazard posed
by the burner.
If the machine is to be operated
indoors, the local building
regulations must be observed for
the discharge of the exhaust
fumes into the atmosphere.
Ensure an adequate supply of
fresh air.
If the machine is to be connected
to a flue gas stack, the state
building regulations must be
observed. We will be glad to
provide tips for connection
systems, on request.
The machine must be supervised
at all times so that the operator
can notice when the flame goes
out.
ð Secure the machine with
the parking brake (Fig. 2).
ð Check the oil level in the
high-pressure pump (Fig. 3).
ð Fill the cleaning agent tank
with prediluted Alto cleaning
agent.
ð With the machine cold:
Pour fuel (fuel oil EL, biodiesel
E to DIN 51 606 or diesel fuel
to DIN 51 603) into the fuel
tank.
The fuel must be free from
contamination.
Tank capacity: 30 litres
1)
Option / model variants