ATTIX 550-01/550-11 MOBIL/550-21/590-21
ATTIX 12 GALLON / ATTIX 12 GALLON RDF
ATTIX EC 12 GALLON AS/E
23
1)
Option depending on model
9.2 Guarantee Our general conditions of busi-
ness are applicable with regard
to the guarantee.
Subject to change as a result of
technical advances.
‡ Reduced suction power > Suction power selected with
suction power control
1)
is to
low.
> Clogged suction hose/noz-
zle.
> Seal/tank rim between the
upper section of the cleaner
and the dirt tank is dirty/de-
fective.
> Filter bag is full.
> Filter element is clogged.
· Set suction power in ac-
cordance with section 4.2.3.
"Suction power control".
· Clean suction hose/nozzle.
· Clean/replace seal.
· See section 7.2.2 "Replac-
ing the fi lter bag".
· See section 4.3 "Cleaning
the fi lter element" and 7.2.3
"Replacing the fi lter ele-
ment".
‡ No suction power during wet
cleaning
> Tank is full (fl oater closes
the suction opening).
· Switch off the cleaner.
Empty the tank.
‡ Voltage fl uctuations > Impedance of power supply
is too high.
· Use a suitable extension
cord (see section 9.4 "Tech-
nical data").
· Connect the cleaner to
another socket closer to
the fuse box. Voltage fl uc-
tuations over 7 % should
not occur if the impedance
at the transfer point is
≤ 0.15 Ω.
Fault
Cause
Remedy
9 Further information
9.1 Recycling the vacuum
cleaner
Make the old cleaner unusable
immediately.
1. Unplug the cleaner and
cut the power cord.
The cleaner contains valuable
materials that should be re-
cycled. Therefore, make use of
your local waste disposal site.
Contact your local authorities or
your nearest dealer for further
information.