Nilfisk-ALTO 550-11 Mobil Vacuum Cleaner User Manual


 
ATTIX 550-01/550-11 MOBIL/550-21/590-21
ATTIX 12 GALLON / ATTIX 12 GALLON RDF
ATTIX EC 12 GALLON AS/E
22
1)
Option depending on model
Check it for damage and
replace if necessary.
5. Check antistatic clamp (5)
for damage and have it
replaced by Alto Service if
necessary.
6. Check the oater (6) for
proper operation: When
you turn the lter holder, the
oater should move back
and forth easily.
7. Fit a new lter element.
8. Fit the lter holder and turn it
clockwise to secure it.
9. Dispose of the used lter
element in accordance with
legal regulations.
CAUTION!
Never use the vacuum clean-
er without a lter.
6
4
5
8 Troubleshooting
Fault
Motor does not start > Fuse in mains plug has
blown.
> Overload protection switch
has tripped.
> Self-acting carbon brush is
worn
1)
Reset the fuse.
Switch off the vacuum clea-
ner and allow it to cool for
approx. 5 minutes. If it can
not be started again, contact
the Alto service department.
Have carbon brushes
changed by Alto Service.
Motor does not run in auto-
Cause
Remedy
matic mode
1)
> Power tool is defective or
not connected properly.
> The power rating of the elec-
trical tool is too low.
Check that the power tool
works or that the plug is
inserted correctly.
Note that minimum power
rating is P>40W