Dust Class M (medium). The dusts which belong to this class
are: dusts with OEL values
1)
> 0.1 mg/m³ as well as saw dust.
The machine is tested in its entirety by vacuums for this dust
class. The maximum degree of permeability is 0.1% and the dis-
posal must be low dust.
The air flow in Safety Vacuum systems has to be strictly controlled
to achieve a minimum flow rate of V
min
= 20 m/s in the suction hose.
The vacuum cleaners ATTIX 30-XH and ATTIX 50-XH are suitable
to pick up
dry, nonflammable dust, non flammable liquids, hazadous dusts
with OEL values, carcinogenic dusts, dusts containing germs
The vacuum cleaners ATTIX 30-XH PC e ATTIX 50-XH PC are also
approved for asbestos abatement (TRGS 519).
The vacuum cleaners ATTIX 30-XM and ATTIX 50-XM are suitable
to pick up
dry, nonflammable dust, non flammable liquids, sawdust and
hazadous dusts with OEL values > 0.1 mg/m³
The vacuum cleaners are suitable for commercial use, such as e.g.
in
Hotels, Schools, Hospitals, Factories, Shops, Offices, Hire shops
Any other use is considered as improper use. The manufacturer ac-
cepts no liability for any damage resulting for such use. The risk for
such use is borne solely by the user.
Proper use also includes proper operation, servicing and repairs as
specified by the manufacturer.
Transport
1. Before transporting the dirt tank, close all the locks.
2. Do not tilt the cleaner if there is liquid in the dirt tank.
3. Do not use a crane hook to lift the cleaner.
Storage
1. Store the appliance in a dry place, protected from frost.
Maintenance, cleaning and
repair
During the following work, ensure that dust is not unnecessarily
spread around. Wear a P2 bresthing mask.
CAUTION: In the case of asbestos abatement wear additional sin-
gle-use clothing.
Electrical connection
1. It is recommended that the vacuum cleaner should be connected
via a residual current circuit breaker.
2. Arrange the electrical parts (sockets, plugs and couplings) and
lay down the extension lead so that the protection class is main-
tained.
3. Connectors and couplings of power supply cords and extension
leads must be watertight.
Extension lead
1. As an extension lead, only use the version specified by the man-
ufacturer or one of a higher quality. See operating instructions.
2. When using an extension lead, check the minimum cross-sec-
tions of the cable:
Cable length Cross section
< 16 A < 25 A
up to 20 m 1.5 mm
2
2.5 mm
2
20 to 50 m 2.5 mm
2
4.0 mm
2