REPLACING FILTER ASSEMBLY-
AirTube & Air Tube Supreme
Step 2
Gently lay unitup-side down.With
a screw driver,remove all4 screws.
Step 3
Removelid bypulling slightlyon
cover.
Step 1
Turn Power Off and
unplug receptacle.
Step 6
A-To replace pre-filter,gently
removepre-filter from Carbon
canister andreplacewith newone.
B-To replace Anti-microbialfilter,
peel offfilter liner.
Step 4
Firstremove HEPA filter by placing
your handon theinner sideof the
filter.
Thenpullup gentlyuntiltotallyout.
Step 5
NowremoveCarbonfilterbyplacing
hands onthe innerside ofthe filter.
Thenpullup gentlyuntiltotallyout.
Step 8
Place lidback to itsproper position
by aligningscrew holes.
Step 9
With ascrew driver,place 4
screws back intotheir positions.
Step 7
Replace allfilters withnew ones
then reassemble by inserting the
Carbon filter firstthen theHEPA.
A
B
Congratulations, you are moments away from fresher, cleaner indoor air.
Your new AllerAir unit will combat many of the chemicals,gases, odors and
particles responsible for p oor indoor air qualit y, and in turn, health concerns
such as allergies, asthma,sick building syndrome and multiple chemical
sensitivity. As with any air cleaner, proper maintenance of your unit is a vital
part of keeping it operating at peak efficienc y.
AllerAir Industries Inc.
AirTube Series
Operation:
Your unit is shipped fully assembled and ready for use. Plug into 120V-
15amp outlet. For best results situate your unit close to your sitting,
sleeping or work area.
NOTE: Please save your packaging. Original packaging will be required for
all warranty returns.
WARNING !
Before removing the top or bottom of the unit for any
reason, always unplug the cord from the power supply.
Maintenance:
AirTube & Air Tube Supreme
The HEPA Filter(Model AirTube HEPA)
Should be changed af ter
approximately 24 months of use
in an average home environment.
A noticeable lessoning of air flow
is a sign that it may be time to
replace this filter.
The Carbon Filter(Model AirTube Carbon)
Should be changed af ter
approximately 12 months of use
in an average home environment.
A noticeable decrease in air
quality could also be a sign that it
may be time to replace this filter.
The Pre-filter (Model AirTube Prefilter)
Replace or vacuum from the
outside of the unit ever y 2-3
months.
AirTube Jr.
The Electrostatic HEPA Filter
(Model AirTube Jr.Elec trostatic HEPA)
Should be changed af ter
approximately 12 months of use in
an average home environment.
A noticeable lessoning of air flow
is a sign that it may be time to
replace this filter.
The Carbon Filter (ModelAirTube Jr.Carbon)
Should be changed af ter
approximately 9-12 months of use
in an average home environment.
A noticeable decrease in air
quality could also be a sign that it
may be time to replace this filter.