16
en
30
31
•Turntheplasticcupandcartridgeoverandshakeuntil
allgranulesareinthecartridge(37).
•Removetheplasticcupandthepinkstyrofoampiece
fromthecartridge(38)andretainforfutureuse(the
refillgranulesconsistsof3refillbags)(39).
•Closethecartridge(40).
•Soakthedemineralizationcartridgeinawaterbath
24hoursbeforeusingit(43).Thegranuleshavetoab
sorbwatertoreachhighperformance.Ifthecartridge
issoakedinthetank,makesuretoexchangethewater
andemptythewaterfromthebasebeforeusingthe
humidifier.
•Screwthecartridgeonthewatertankcap(44).
•Screwthecartridgeonthebottomsideofthewater
tank,putthetankonthemainbody(45).
Placinggranulesinthecenterofthecartridge
allowsthemtoescapeintheunitortoclogthe
unit.Theunitwillnolongeroperateproperlyand
thegranulesneedtobecleanedoutthoroughly.
Option B: replace the whole cartridge
•Removethewatertankfromthebaseandunscrewthe
watertankcap(30).
•Thedemineralizationcartridgeisattachedtothetank
cap.Unscrewthecartridgefromthecapbyturningit
counterclockwise(31).Important:doNOTdisposeof
thewatertankcap!
• Throwthewholecartridgeintothewaste(41).
•Unpackthenewcartridge(42).
•Soakthedemineralizationcartridgeinawaterbath
24hoursbeforeusingit(43).Thegranuleshavetoab
sorbwatertoreachhighperformance.Ifthecartridge
issoakedinthetank,makesuretoexchangethewater
andemptythewaterfromthebasebeforeusingthe
humidifier.
•Screwthecartridgeonthewatertankcap(44).Close
tankcapwellandplacethetankonthemainbody
(45).
Replacement of the demineralization
cartridge
Always unplug the unit before removing the
watertank.Donottouchthewaterinthebase
duringoperation!
Thewatertankisequippedwithademineralizationcart
ridge.Thiscartridgehastobereplacedevery2–3months.
Ifthewaterisveryhard,itmaybenecessarytoreplacethe
cartridgeearlier.Whitedustaroundthedeviceisasuresign
thatthecartridgeneedsreplacing.Ifwhiteresiduestillforms
aroundthedeviceafteranewcartridgehasbeeninserted,
pleasemakesurethatthewateryouareusingisuntreated.
Ifthewaterflows
throughadecalcificationsystem–suchas
anionexchanger–(sodiumisaddedtoremovecalcium)in
thebuildingbeforeitisusedinthehumidifier,saltcanpre
cipitateaswhitedustaroundthedevice.Thedemineralization
cartridgeorthegranulesmustbeexchangedatthelatest
after6monthsortheunitdoesnotreachitsfullperformance
anymore.
Option A: replace the granules
•Removethewatertankfromthebaseandunscrewthe
watertankcap(30).
•Thedemineralizationcartridgeisattachedtothetank
cap.Unscrewthecartridgefromthecapbyturningit
counterclockwise(31).Important:doNOTdisposeof
thewatertankcap!
•Openthecartridge(32).
•Throwthecontentintothewaste(Attention!Disposed
granulescanmakethefloorslippery!)(33).
•Placetheenclosedpinkstyrofoampieceinthecenter
ofthecartridge.Donotpushittothebottomasitwill
bedifficulttoremoveafterwards(34).
•Pourthecontentsofonerefillgranulesbagintothe
plasticcupthatisincludedwiththerefillgranulespa
ckaging(35).
•Placetheemptycartridgewiththepluginthecenter
ontotheplasticcup(36).
32 33