Air King 9898L Fan User Manual


 
1. Connect the black wire in the light fitter with the blue wire
marked “For Light” using the supplied wire nuts.
(Figure 8)
2. Connect the white wire in the
light fitter with the white wire
marked “For Light” using the
supplied wire nuts.
3. Tuck the wires and wire nuts into
switch cup. Lift the light fitter
into place and insert the three
screws and tighten.
4. Install light bulb (not included)
and lift globe into place and
secure with the three thumb
screws. Do not overtighten.
2. Place one of the phillips pan head screws into one of the
recessed holes in the blade bracket. Turn screw until it
mates with threaded hole in hub. Do not tighten screw
completely at this time.
(Figure 7)
3. Install the second screw
in the same manner,
then tighten both
screws firmly.
4. Install the remaining
blade assemblies by
repeating the above
steps.
52" PORCH CEILING FAN
NOTE: The blades should be attached to the fan after it is
hung and wired to prevent blade brackets from being bent
and causing the fan to wobble.
BLADE ASSEMBLY AND
INSTRUCTION MANUAL
Model 9898L
MAINTENANCE
Periodic cleaning of your ceiling fan is the only maintenance
that is needed. When cleaning, use only a soft brush or lint
free cloth to avoid scratching the finish. Abrasive cleaning
agents are not required and should be avoided to prevent
damage to the finish. Do not spray water directly onto your
ceiling fan. It could damage the motor or the blades and create
the possibility of an electrical shock or fire.
WARRANTY
The ceiling fan you have purchased is warranted by the
manufacturer for one year from the date of purchase against
defects in workmanship and/or materials. The motor is
warranted for ten years. This warranty means that only the
parts that prove to be defective during the period of warranty
will be either repaired or replaced at our option. The right is
reserved by the manufacturer to replace the whole product
in lieu thereof. Should repair become necessary during the
warranty period, write to: AIR KING c/o LASKO PRODUCTS,
INC., Appliance Service Department, 820 Lincoln Ave., West
Chester, PA 19380. Describe the problem you are having. DO
NOT SEND FAN!
This warranty does not apply if the damage occurs because
of accident, improper handling, installation or operation,
shipping damage, abuse, misuse or unauthorized repairs made
or attempted. ALL WARRANTIES, EXPRESSED OR IMPLIED
LAST FOR ONE YEAR FROM DATE OF ORIGINAL PURCHASE,
EXCEPT FOR THE MOTOR. THIS WARRANTY DOES NOT
COVER LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL
DAMAGES FOR ANY CAUSE WHATSOEVER. Some states do
not allow limitations on how long any implied warranty lasts,
or the exclusion or limitations of incidental or consequential
damages, so that the above limitation or exclusion may not
apply to you. This warranty gives you specific legal rights,
and you may have other rights that vary from state to state.
FOR REPLACEMENT PARTS: Please call 1-800-966-2028,
Monday - Friday, between the hours of 8am and 4 pm EST.
Reference the type and style of product when you call.
FOR QUESTIONS OR COMMENTS ABOUT YOUR CEILING
FAN: Please call 1-800-233-0268, Monday - Friday, between
the hours of 8am and 4pm EST.
New 11/00
Your new ceiling fan is UL listed and will require a grounded
electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.
The 52" total fan weight is 26 lbs maximum.
WARNING: To reduce the risk of fire, electrical shock or
personal injury, mount fan at least 7 feet above the floor to
an outlet box marked “Acceptable for fan support.” Use
screws provided with outlet box. Most outlet boxes commonly
used for the support of lighting fixtures are not acceptable
for fan support and may need to be replaced. Consult a
qualified electrician if in doubt.
Your ceiling fan will fit any of the following electrical boxes:
4" octagon box, 3" octagon box, 1/2" deep ceiling pan, or a
plaster ring with 3 1/2" mounting hole centers mounted on
one of the above listed boxes. Your new fan will also install
on a “wiremold” No. 5738 fixture box. The electrical box must
be securely anchored an capable of withstanding a load of at
least 50 pounds.
If your ceiling fan does not have one of the above electrical
boxes for proper wiring, you may wish to contact a licensed
electrician for installation.
READ AND SAVE THESE
Remove the three shipping
stabilizer tabs from the
bottom of the fan.
Remove Remove
1. Using three phillips washer head screws, secure one
bracket to each of the blades. Complete this assembly
before attaching blades to ceiling fan.
(Figure 6)
Figure 6
Phillips Washer
Head Screw
Blade Bracket
Blade
Screws
Figure 7
Motor Hub
Blade
Bracket
Phillips Pan
Head Screw
USING YOUR CEILING FAN
1. Restore power to the electrical box.
2. Check the operation of the fan
by gently pulling the chain
switch.
3. To reverse airflow direction, turn
fan off and wait for the blades
to come to a full stop, then slide
reversing switch to opposite
position.
(Figure 9)
4. Your ceiling fan is equipped
with four position, three speed
pull chain switch.
Figure 9
Reversing Switch
LIGHT KIT INSTALLATION
Figure 8
White
Wires
Blue
Wire
Black
Wire
Scre
Light
Fitter
Globe