Air King 9320 Furnace User Manual


 
CAUTION: THE SECONDARY SUPPORT CABLE PROVIDED SHOULD BE USED ANYTIME THE CIRCULATOR IS MOUNTED OVERHEAD FOR
ADDITIONAL SAFETY.
SECONDARY SUPPORT CABLE
(Figure 2)
1. Loop one end of Cable around the Large Diameter Wires of both the Front and Rear Circulator Guard.
2. Attach a Cable Clamp with the "U" on the tail side of the loop leaving a tail approximately 1 to 2 inches. Tighten Clamp Nuts. Make sure
no part of the Cable interferes with the Blade.
3. Wrap the other end of the Cable around a secure building joist, truss, or other support near the Fan. Do not attach cable to I-Beam mount
pipe.Take up all excess slack in the Cable.
CAUTION: USE ONLY THE MOUNTING HARDWARE WHICH IS RECOMMENDED FOR USE
ON THIS FAN.
4. Attach the remaining Cable Clamp as indicated in Step 2. The excess tail should be trimmed to extend 1 to 2 inches past the Clamp.
5. Check the Assembly to assure the Blade is free of all obstructions.
CAUTION: Use of the secondary support cable does not guarantee protection against injury of persons, mounting of both the
circulator and cable could fail if subjected to abuse, neglect or improper installation.
OPERATING INSTRUCTIONS
1. TO OPERATE: Plug cord into a grounded 120V, 60 Hz outlet. Select desired operating speed with pull cord on the rear of the motor:
First pull: High Second pull: Medium
Third pull: Low Fourth pull: OFF
WARNING:
This fan should be used only in a clean, dry environment.
Mounting of this product in any way other then specified in the instruction sheet
will null and void the manufacturers warranty.
MAINTENANCE
WARNING: ALWAYS UNPLUG THE CORD BEFORE MOVING OR SERVICING.
WARNING: DO NOT IMMERSE FAN IN WATER!
CLEANING: Use a soft cloth and mild soap solution such as liquid dish washing detergent. Dry all parts completely before reconnecting to
power supply.
CAUTION: Do not use gasoline, benzine, thinner, harsh cleaners, etc. as they will damage the Fan. NEVER use ALCO-
HOL OR SOLVENTS.
SERVICING: All other servicing, with the exception of general user maintenance, should be performed by an authorized service representa-
tive. Call 1-800-233-0268, Monday through Friday, between the hours of 8:00 a.m.and 5:00 p.m. for the location of your nearest service
center.
LUBRICATION: Precision bearings are sealed at the factory for life and do not require further lubrication.
STORAGE: Store the Fan, with these instructions, in a clean and dry place.
IMPORTANT INSTRUCTIONS - OPERATING MANUAL IMPORTANT INSTRUCTIONS - OPERATING MANUAL
DESCRIPTION
1. For mounting listed Air King® circulators from the ceiling.
2. Distance mounted from the ceiling can be changed by using a length of 1-1/2” NPT pipe. Simply substitute your pipe for the provided pipe
nipple.
CEILING MOUNT INSTALLATION
1. Locate the four hole pipe flange, securely mount to ceiling structure. Ensure ceiling structure can safely support the installed Fan.
2. Screw pipe nipple, (or your longert pipe), into adapter. Pipe nipple must be screwed in at least 4 full revolutions.
3. Tighten provided 1/4” set screw in the yoke adapter.
4. Screw the yoke with adapter assembly onto the pipe. This assembly must also be turned at least 4 full revolutions into the pipe flange.
5. Tighten the 1/4” set screw in the adapter down securely onto the pipe nipple.
CAUTION: FAN IS HEAVY AND MAY REQUIRE TWO PEOPLE TO MOUNT.
6. Align Yoke with grill mounting threads. Loosely attach one Grill Knob and one Rubber Spacer to the Head Assembly. Attach the other Grill
Knob and Rubber Spacer to the Head Assembly and FIRMLY tighten. Return to the first Grill Knob and FIRMLY tighten.
(Figure 1)
2Rev. A 6/04
5084423
3Rev. A 6/04
5084423
Yoke
Rubber
Spacer
Figure 1
Large Guard
Wires
Figure 2