Air King 5AU42/9215 Air Conditioner User Manual


 
MODELO
5AU42/9215
SPEED
ALTA MEDIA BAJA
FPM* 715 580 455
RPM 1400 1140 875
Amps 0.36 0.30 0.25
Watts 43 35 30
dB A 45 39 33
MODEL 2535
Rev. B 7/05
3
9215ES
Rev. B 7/05
6
9215ES
REMOTE CONTROL
(Figure 6)
1. Install the two “AAA” batteries supplied as shown in
Figure 6
.
2. The Remote Control Power Button is labeled as (
).
3. All the functions performed with the Remote Control work
identically to the Manual Controls.
MODEL 5AU42/9215
MODELO 5AU42/9215
ARMADO
1. Para facilitar el armado, recueste el Ventilador de modo que la
parrilla negra y el tablero de control den hacia arriba.
2. Localice el
Cable Eléctrico
en la parte inferior del Ventilador.
Coloque el
Cable Eléctrico
en los
Canales Para Cable
de los
Soportes De Columna
. Encaje firmemente los
Soportes De
Columna
el uno con el otro de modo de formar un
Conjunto De
Soportes De Columna
.
(Figura 1)
3. Una el
Conjunto De Soportes De Columna
a la
Base Del Motor
con
(4) Tornillos M5 de 1/2”de largo
. Cerciórese de alinear la
Llave
del
Conjunto De Soportes De Columna
con la
Muesca
Localizadora
de la
Base Del Motor
.
(Figura 1)
4. Arme las Bases de Soporte, introduciendo las
Copas
en la
Base
de Soporte A
en los
Orificios De Copas
de la
Base de Soporte
B
. Pase el
Cable de Electricidad
por el orificio grande en el
centro del Conjunto de la Base de Soporte.
(Figura 2)
5. Fije los
Tornillos (2) #8 X 1/2”
en los cuatro orificios que se
encuentran en la parte inferior de la base.
(Figura 3)
Cable
Eléctrico
Canales
Para Cable
Soportes
De Columna
Base Del
Motor
Muesca
Localizadora
Tornillos
M5 de 1/2”
Conjunto De Soportes De Columna
Llave
Soportes
De Columna
Figura 1
OPERATION
This Fan may be operated by the Manual Controls located on top
of the unit (as shown in
Figure 5
) or by the Remote Control
(shown in
Figure 6)
.
1. Remove the Fan from the carton and assemble as instructed.
2. Place the Fan on a firm, level surface.
WARNING: Plastic or rubber tabs, like the feet on this unit, may
stick to hardwood floors. The unit may leave a residue that could
darken, stain or leave permanent blemishes on the finish of certain
hardwood floors.
3. Plug the power supply cord into a 120 V~ electrical outlet. Be
sure plug fits tightly in outlet.
4. When the Fan is plugged in, there will be a “beep” to indicate
there is power to the unit.
5. Turn the Fan ON by pressing the
Power Button
( ). The Fan will
“beep” twice to indicate that the unit has been turned ON.
6.
SPEEDS: Press the
Fan Speed Button
( ) to desired speed
setting. Each time the Fan Speed Button is pressed, the speed
will change from Low (1), to Medium (2), to High (3). When intially
plugged in, the Fan will be in Low Speed. When the Fan is turned
OFF and ON again, the unit will resume the speed at which it
was turned OFF.
7.
OSCILLATION: Press the
Oscillation Button
( ) to start and
stop the oscillation function.
8.
TIMER: The timer function allows the unit to be set to operate
for a length of time from 1/2 hour to 7 1/2 hours, in increments of
a 1/2 hour. Press the
Timer Button
( ) to set the length of time
desired. Each time the timer button is pressed, the time is
increased by 1/2 hour. After reaching 7 1/2 hours, pressing the
Cable
Eléctrico
Base de
Soporte B
Base de
Soporte A
Copas
Conjunto de la Base de Soporte -
Vista des de Arriba
Figura 2
Conjunto de la Base de Soporte -
Vista des de Abajo
Conjunto
de la Base
de Soporte
#8 X 1/2”
Tornillos
Cable
Eléctrico
Figura 3
6. Align the
Support Base Assembly
with the
Column Support
Assembly
, noting that the cord channel on the bottom of the
support base should be towards the back of the Fan.
Assemble the
Support Base Assembly
to the
Column
Support Assembly
with
(4) 1” Long M5 Screws
. Gently pull
any excess slack of the
Power Supply Cord
and place it in the
Wire Locating Trough
.
(Figure 4)
M5 X 1”
Screws
Support
Base
Assembly
Column
Support
Assembly
Power
Supply
Cord
Wire
Locating
Trough
Figure 4
Column to Base Assembly
Figure 5
Remote Storage
Front of
Remote
Back of
Remote
Figure 6
timer button once more will reset the Fan to continuous running.
The lights on the front of the unit will light up appropriately with
the length of time that the Fan is set for.
9.
SLEEP: This function allows the unit to be set in Sleep Mode.
Pressing the
Sleep Button
( ) once will set the unit on Low for 6
continuous hours. Pressing the
Sleep Button
( ) a second time
will reset the unit to 6 continuous hours. The Oscillation Button
(
) will function when the Fan is in Sleep Mode. Pressing any
other button (Timer, Fan Speed or the Power Button) will shut off
the Sleep Mode.
10.To turn the Fan OFF, press the
Power Button
( ) and unplug the
unit from the electrical outlet.
DESCRIPCIÓN
El Ventilador de Pedestal AirKing de 16" (40.6 cm) es operado mediante
una perilla rotatoria de 3 velocidades; además, es de altura ajustable. Su
unidad giratoria de 3 paletas, de 16" (40.6 cm), es accionada por un motor
de condensador de división permanente con un cordón eléctrico de 6' (1.8
m) pies 18/3.
ESPECIFICACIONES
Motor ...................................... 120V, 50/60Hz
Tamaño de paletas ................ 3.5" ( 8.89 cm)
Velocidades ........................... 3
Control ................................... Conjuntor Rotario / Control Remoto
Distribución del lujo de aire ... 90° Variable
Aprobaciones ......... Catalogación UL. El protector de malla
cerrada del ventilador satisface las normas
OSHA.
* Measured @ 4 feet