Aiphone JF-DVF-HID-I Home Security System User Manual


 
JF-2MED
JF-DVF-HID-I
PS-1820UL
+
-
+
-
1A1
1A2
B1
B2
2A1
2A2
S
S
A1
A2
WIRING DIAGRAM:
TESTING AND OPERATION:
SPECIFICATIONS:
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
Page 2
JF-DVF-HID-I Instr.
0810JD
FCC WARNING:
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference that may cause undesired operation.
For proper regulatory compliance, the drain wire should be disconnected at the
power supply end of the cable.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
The Reader is intended to be powered from a limited power source output of a
previously certified power supply.
When power is applied to the iClass reader, the LED will turn RED while the beeper beeps
simultaneously 3 times. (The last tone is a higher frequency). The LED will then flash once after the
last tone. This indicates that the microcontroller is operating properly.
Present an
iClass ID card to the reader (Hold the card directly in front of reader). The LED will
momentarily turn green while the beeper beeps once, indicating that the card was read successfully.
CARD READER:
Power Source: 10 ~ 16V DC
(linear recommended)
Current Requirements: 80mA (Avg); 300mA (peak)
@ 12V DC
Transmit Frequency: 13.56 MHz
Terminations: Color-coded pre-wired pigtails
Wiring Distance: 500'
Operating Temperature: -10°~60°C / 14°~140°F
Operating Humidity: 5-95% relative humidity
non-condensing
CAMERA:
Camera unit: CCD Camera
Scanning line: 525 lines
Min. illumination: 5 Lux at 1' or less
Terminations: Screw terminals
Wiring Distance: 330' w/871802 wire
980' w/JBW-BA & 851602 wire
Dimensions (camera): 5-¾” W x 11-” H x 1-5/16" D
With SBX-DVF-P: 5-15/16" W x 11-¾” H x 2-13/16" D (Top)
1-15/16" D (Bottom)
TOLL FREE TECHNICAL SUPPORT:
(800) 692-0200
E-MAIL: tech@aiphone.com
Wiegand Wire Color
+ DC (10-16V) Red
Ground Black
Data0 Green
Data1 White
Shield Ground Drain
Green LED Orange
Red LED Brown
Beeper Yellow
Hold Blue
--- Violet
Connect the reader to the host according to the
wiring table below and the host installation guide.