Aico Ei261DENRC Carbon Monoxide Alarm User Manual


 
1. IMPORTANT INFORMATION
WARNING: The Alarm should be permanently wired to the mains by a qualified electrician in accordance
with IEE wiring regulations (BS7671).
Install a Carbon Monoxide (CO) Alarm in every room that contains a fuel burning appliance,
particularly rooms where people spend a lot of time e.g. bedrooms, kitchens and sitting rooms.
In rooms with an appliance, install (preferably) on the ceiling (300mm from walls and between 1m
to 3m horizontally from appliance). In rooms remote from the appliance install at breathing level,
where the light indicators can be seen.
Regularly check that the green power light is on, so that rechargeable back-up cells will remain fully
charged. Important: The CO Alarm will not work if the mains supply is off and the rechargeable
cells are depleted.
Test the unit weekly by pressing and holding the Test/Hush button. The horn will sound.
Replace sensor module after 5 years operation (see page 23).