Aero Mist 60100K Humidifier User Manual


 
Regulator
(Normal operating pressure 800-1000 PSI.
Pressure not to exceed 1000 PSI)
Liquid-Filled
Pressure Gauge
Outlet
To Misting Feed Line
Automatic
Drain Valve
Oil Filler/Breather Cap
Oil Sight Glass
Oil Drain
On/Off Switch
Power Cord
Water Inlet
Filter Bowl
With Replaceable 5-Micron Filter Element
LIST OF ALL ENCLOSED PARTS
QTY PART NO DESCRIPTION
1 60100K Direct-Drive Pump
1 56402 Flexible Nylon Tubing 25' Roll
1 52000 Automatic Drain Valve
57020 MAINTENANCE KIT
QTY PART NO DESCRIPTION
1 57011 Filter Element
1 57025 Pump Oil
WARNING: Before plugging in the unit for the fi rst time, read the following section carefully. To reduce the risk of
electric shock. Plug in supplied grounded cord into a properly grounded receptacle. When servicing this unit, unplug
power cord before attempting any service or repairs.
Install pump above grade level on a pre-formed concrete pad, 16"×16" minimum size.
Plug power cord of unit into a properly grounded receptacle.
Connect water line to water inlet connector.
Unit is pre-fi lled with oil and ready to run. Oil should be half full on the sight glass when unit is off. Do not overfi ll
.
On new misting systems, fl ush lines before installing nozzles. The pump will not build pressure until all nozzles are installed.
Do not exceed 1000 PSI and do not run pump without water.
Winter shutdown: Unplug pump power cord, shut off water supply, remove fi lter bowl and drain water. Also drain water out of all lines, to
prevent damage to pump or lines.
25 feet or more of nylon tubing is recommended in order to reduce vibration noise.
ANNUAL MAINTENANCE INSTRUCTIONS
Change oil every 500 hours of runtime or once a year. Use approved Pump Oil (52025). Oil should be half full on the sight glass when
unit is off. Do not overfi ll
.
Change Filter Element Annually
INSTALLATION INSTRUCTIONS
DIRECT DRIVE PUMP SPECIFICATIONS
MODEL FLOW VOLTS MOTOR PUMP LOAD DIMENSIONS
GPM 60 Hz HP RPM Amps L x W x H
60100K 1.0 120 0.75 1725 10.4 24x15x13
Maximum pressure is 1000 PSI, normal operating pressure is 800-1000 PSI.
RECOMMENDED MIN-MAX NOZZLE RANGE
NOZZLES NOZZLES NOZZLES
Nozzle Size .014 .012 .008
Nozzle Range 12–25 15–30 22–45