Admiral ADM8IA - 10080010 Carpet Cleaner User Manual


 
MAINTENANCE
ADMIRAL 86038270 05/22/07
17
!
WARNING:
SOLUTION PUMP REPLACEMENT
1. Turn off all switches and unplug the machine.
2. Remove recovery tank.
3. Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the
frame.
4. Remove solution hoses from fittings in pump.
5. Remove the (2) screws that fasten the pump to the frame.
6. Reverse process to install pump.
ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM THE FOLLOWING REPAIRS.
BELT REPLACEMENT
1. Turn off all switches and unplug machine.
2. Remove recovery tank and brush.
3. Remove the (2) screws that fasten the solution tank
to the frame, and tilt tank back to expose the inside
of the frame.
4. Loosen the (4) screws that hold the brush motor in
place and slide motor forward to release tension in
belt.
5. Remove the (2) screws that fasten the vacuum shoe
links (p/n 86227350 – PRV NO. 05016) to the brush
housing.
6. Remove the (3) screws that fasten
the side plate (p/n 86249420 – PRV
NO. 62759) to the brush housing to
remove belt.
NOTE: All components associated with
driving the brush will come out with the
side plate.
7. Reverse process to install belt.
86249420
PRV NO. 62759
86227350
PRV NO. 05016
Pressure Switch
86161980
PRV NO. 42-809332
Valve Asm
86258830
PRV NO. 84161
Diaphragm
86003400
PRV NO. 29206
Pump Replacement Parts for Shurflo 100 psi (86026400 – PRV NO. 65254)
PumpHead
86251040
PRV NO. 65187
Motor
86247370 - PRV NO. 53246
Diaphragm
86235120
PRV NO. 29219
Pump Head
86251090
PRV NO. 65204
Valve Asm
86258860
PRV NO. 84166
Pump Replacement Parts for Flojet 100 PSI 230V (86004770 – PRV NO. 47477)