Admiral AAW-24CM3FHU Air Conditioner User Manual


 
4
1. All wiring must comply with local and national
electrical codes and must be installed by a
licenced electrician. If you have any questions
regarding the following instructions, contact a
licenced electrician.
2. Check available power supply and resolve any
wiring problems BEFORE installing and operating
this unit.
3. For your safety and protection, this unit is
grounded through the power cord when
plugged into a matching wall outlet. If you are
not sure whether your wall outlet is properly
grounded, please consult a licenced
electrician.
4. The wall outlet (3-pin) must match the plug
(3-pin) on the power cord supplied with the unit.
DO NOT use plug adapters or extension cords.
See (Table 1) for receptacle and fuse information.
5. The rating plate on the unit contains electrical
and other technical data. The rating plate is
located on the right side of the unit. Make sure
to use the correct power supply according to the
rating plate of your air conditioner.
Table 1
If the air conditioner has a serial plate rating
of 115 volts and up to and including 7.5 amps,
the unit maybe on a fuse or circuit breaker
with other devices. However, the maximum
amps on all devices for that fuse or circuit
breaker can not exceed the amps of the fuse
for the circuit breaker.
If the air conditioner has a serial plate rating
of 115 volts and greater than 7.5 amps it
must have its own fuse or circuit breaker,
and no other device or unit should be
operated on the fuse or circuit breaker.
If the air conditioner has a serial plate rating
of 230 volts, it must have its own fuse or
circuit breaker, and no other device or unit
should be operated on the fuse or circuit
breaker.
To avoid the possibility of personal injury,
disconnect power to the unit before installing
or servicing.
Electric Shock Hazard
Electrical specifications
!
125
10K-12K
(Cooling only)
24K
(Cooling only)
15
15
RATED VOLTS
COOLING CAPACITY
250
AMPS
FUSE SIZE
WALL OUTLET
20
20
RECEPTACLE AND FUSE TYPES
18K(Cooling only)
10K-12K(With heating)
15
30
30
15
250
250
18K-24K
(With heating)
Note:10K-12K(Cooling only) including models AAW-10CR1FHU
AAW-10CM1FHU
AAW-12CR1FHU
AAW-12CM1FHU
18K(Cooling only) including models AAW-18CR3FHU
AAW-18CM3FHU
10K-12K(With heating) including models AAW-10DR3FHU
AAW-12DR3FHU
24K(Cooling only) including models AAW-24CR3FHU AAW-24CM3FHU
18K-24K(With heating) including models
AAW-18DR3FHU
AAW-24DR3FHU