Admiral AAW-10CM1FHUE Air Conditioner User Manual


 
1. All wiring must comply with local and national
electrical codes and must be installed by a
licensed electrician. If you have any questions
regarding the following instructions, contact a
licensed electrician.
2. Check available power supply and resolve any
wiring problems BEFORE installing and operating
this unit.
3. For your safety and protection, this unit is
grounded through the power cord when
plugged into a matching wall outlet. If you are
not sure whether your wall outlet is properly
grounded, please consult a licensed
electrician.
4. The wall outlet (3-pin) must match the plug
(3-pin) on the power cord supplied with the unit.
DO NOT use plug adapters or extension cords.
See (Table 1) for receptacle and fuse information.
5. The rating plate on the unit contains electrical
and other technical data. The rating plate is
located on the front of the base pan. Make sure
to use the correct power supply according to the
rating plate of your air conditioner.
125
8K-15K
22K-24K
Table 1
15
15
If the air conditioner has a serial plate rating
of 115 volts and up to and including 7.5 amps,
the unit maybe on a fuse or circuit breaker
with other devices. However, the maximum
amps on all devices for that fuse or circuit
breaker can not exceed the amps of the fuse
for the circuit breaker.
If the air conditioner has a serial plate rating
of 115 volts and greater than 7.5 amps it
must have its own fuse or circuit breaker,
and no other device or unit should be
operated on the fuse or circuit breaker.
If the air conditioner has a serial plate rating
of 230 volts, it must have its own fuse or
circuit breaker, and no other device or unit
should be operated on the fuse or circuit
breaker.
To avoid the possibility of personal injury,
disconnect power to the unit before installing
or servicing.
Electric Shock Hazard
RATED VOLTS
COOLING CAPACITY
250
AMPS
FUSE SIZE
WALL OUTLET
20
20
RECEPTACLE AND FUSE TYPES
!
18K
250
15
15
Note:8K-15K including
AAW-08CR1FHUE
AAW-08CM1FHUE
AAW-10CR1FHUE
AAW-10CM1FHUE
AAW-12CR1FHUE
AAW-12CM1FHUE
AAW-15CR1FHUE
AAW-15CM1FHUE
18K
including
AAW-18CR3FHUE AAW-18CM3FHUE
22K-24K
including AAW-22CR3FHUE
AAW-22CM3FHUE
AAW-24CR3FHUE AAW-24CM3FHUE
6
ELECTRICAL SPECIFICATIONS
WAC 8-24 USER MAN FINAL 3/2/05 12:13 PM Page 8