Adams Low Intensity Infra-Red Heater Electric Heater User Manual


 
GAS BURNER
Burner and controls CSA listed for United States and Canada
Hot Surface ignition and electronic safety– No Pilot
60,000, 80,000, 100,000, 125,000, 150,000, 175,000,
200,000 Btu/hr input sizes (natural or propane gas)
Combustion Air inlet collar
Sight glass for monitoring burner operation
Combustion air proving differential switch
Electrical & gas controls separated from combustion
air stream
Burner Housing 18 GA. galvanized steel
Electrical –120 volt/60/1 ph
CSA listed for Vented or Unvented applications
(
1
)
year limited warranty
TUBE SYSTEM
Combustion chamber–10' x 4" OD, 16 gauge aluminized
steel with flared burner mounting flange
Heat exchanger – as required, remaining system comes
in 10' or 5' 16 gauge aluminized steel
Flared fitting pipe connector with draw bolts at each joint
for solid compression type fitting no gaskets or draw bands
20' to 70' systems Straight systems or optional “L” or “U”
shaped systems using 90 deg elbows. (see schedule for
tube lengths available)
10 year limited warranty
REFLECTORS
High polished parabolic reflectors standard
8' or 4' lengths
Reflector shield and tube system supported by heavy gauge
wire hangers placed approx. 7' apart
Sun-Heat Standard System Features
FLARED PIPE FORMS
Male-Female Type Connection
Compression Fitting
No Clamps or Draw Bands
OPTIONAL FEATURES
Outside combustion air inlet hood with flexible 4" diameter duct
90 deg elbows for “L” or “U” shaped configurations
Diffuser “V” reflector for low mounting applications
Vent cap adapter (4" dia steel to 4" dia class “B” vent pipe
Line voltage thermostat
24 volt relay to convert line voltage thermostat to
24 volt thermostat
Burner “ON” running light