3M NWS100M Water System User Manual


 
5-1
SECTION 5: SPECIFICATION AND OPERATING DATA
Timer Initiated Meter Initiated
ITEM NWS100 NWS150 NWS200 NWS100M NWS150M NWS200M
Nominal Media Volume, cu. ft. (cu mtr) 1.0 (0.03) 1.5 (0.05) 2.0 (0.06) 1.0 (0.03) 1.5 (0.05) 2.0 (0.06)
Salt Dosage, lbs (kg):
Factory Setting (1)
Maximum Setting
6.0 (2.7)
15.0 (6.8) )
9.0 (4.1)
24.0 (11)
12.0 (5.4)
24.0 (11)
6.0 (2.7)
15.0 (6.8) )
9.0 (4.1)
24.0 (11)
12.0 (5.4)
24.0 (11)
Nominal Softening Capacity, Grains (2)
At factory salt setting
At maximum salt setting
18,600
30,000
27,900
45,000
37,200
54,000
18,600
30,000
27,900
45,000
37,200
54,000
Operating Flow Rates, gpm (lpm) (3)
Continuous (no duration limit)
Service (10 minutes or less)
4.0 (15)
7.0 (27)
6.0 (23)
8.0 (30)
7.0 (27)
8.5 (32)
4.0 (15)
7.0 (27)
6.0 (23)
8.0 (30)
7.0 (27)
8.5 (32)
Pressure Loss @ Operating Flow Rates, psi (kPa)
Continuous
Service
6.0 (41)
15.0 (103)
8.0 (55)
15.0 (103)
9.0 (62)
15.0 (103)
6.0 (41)
15.0 (103)
8.0 (55)
15.0 (103)
9.0 (62)
15.0 (103)
Regeneration Flow Rates, gpm (lpm)
Backwash (4)
Brine/Rinse
Rapid Rinse
Brine Refi ll
Approx Water Used
1.5 (5.7)
0.33 (1.25)
1.5 (5.7)
0.5 (1.9)
64 (242
2.4 (9.1)
0.33 (1.25)
2.4 (9.1)
0.5 (1.9)
90 (341)
2.4 (9.1)
0.33 (1.25)
2.4 (9.1)
0.5 (1.9)
91 (344
1.5 (5.7)
0.33 (1.25)
1.5 (5.7)
0.5 (1.9)
64 (242
2.4 (9.1)
0.33 (1.25)
2.4 (9.1)
0.5 (1.9)
90 (341)
2.4 (9.1)
0.33 (1.25)
2.4 (9.1)
0.5 (1.9)
91 (344
Inlet/Outlet Pipe Size, Inches (cm) 1.0 (2.5) 1.0 (2.5) 1.0 (2.5) 1.0 (2.5) 1.0 (2.5) 1.0 (2.5)
Mineral Tank Depth & Height w/Control Valve, Inches (cm) 8x44
(20x112)
10x44
(25x112)
10x54
(25x137)
8x44
(20x112)
10x44
(25x112)
10x54
(25x137)
Overall Depth & Height
w/ Control Valve, Inches (cm)
15x51
(38x130)
15x51
(38x130)
15x61
(38x155
17x51
(43x130
17x51
(43x130
17x61
(43x155)
Brine Tank, W x D x H, Inches (cm) 15x15x34
(38x38x86
15x15x34
(38x38x86
15x15x34
(38x38x86
15x15x34
(38x38x86
15x15x34
(38x38x86
15x15x34
(38x38x86
Approx. Salt Storage, lbs. (kg)
160 (73) 160 (73) 160 (73) 160 (73) 160 (73) 160 (73)
Approximate Shipping Weight, lbs. (kg) 89 (40) 116 (53) 141 (64) 90 (41) 117 (53) 142 (64)
Maximum operating temperature 110°F (43.3°C); Electrical requirements 110V/60Hz (220V/50Hz); Operating pressure 20-100 psi. All types water softener
salt may be used (See MAINTENANCE). Specifi cations subject to change without notice.
NOTES:
1) Meter Initiated Softeners: Dial settings based on this capacity. Consult dealer before changing salt dosage.
2) Actual capacity may vary substantially depending on water analysis and operating conditions. Softening capacities for systems containing 1.0 cubic feet
and larger are based on Radium 226/228, Barium and Softening.
3) For satisfactory performance indicated fl ow rates and duration should not be exceeded. Flow rates specifi ed are adequate for normal residential applica-
tions. Do not use Service Flow Rate when sizing commercial applications or if treated water is to supply a geothermal heat pump, swimming pool, etc.
(contact dealer before selecting equipment).
4) For system to operate properly, pumping rate of well pump MUST be suffi cient to backwash unit at rate specifi ed.