3M
718A Air Ionizer Test Kit
When used with the 3M
718 Static Sensor, the 3M 718A
Air Ionizer Test Kit can provide periodic verification of air
ionizer performance. The 718A consists of a charge plate
and a charger. The system as a whole is designed to meet
the guidelines specified in ESD Association Draft
Standard D3.3.
The charge plate slides over the housing of the 718. Placing
the 718 in the air flow of an air ionizer allows for measure-
ment of the ionizer’s offset balance. The charger can be
used to deposit an electrostatic charge on the plate.
Measuring how long it takes the ionizer to neutralize this
static charge gives the ionizer discharge time.
Calibration and Certification
The 3M 718 Static Sensor can be ordered as calibrated and
certified by a 3M ISO9002 Registered Metrology
Laboratory. Calibration can be traced back to National
Institute of Standards and Technology (NIST) standards, as
specified in MIL-STD-45662.
3M 718A Air Ionizer Test Kit Specifications
Charge Plate Assembly Per ESD Association Draft Standard D3.3
Charge Plate Bracket 1" (H) x 3.1" (W) x 4.25" (L)
Dimensions 2.5 cm (H) x 7.9 cm (W) x 10.8 cm (L)
Charge Plate Area 3.25" (W) x 1.25" (L)
8.3 cm (W) x 3.2 cm (L)
Charge Plate Assembly Weight 2.5 oz (70 g)
Charger Dimensions 0.85" (H) x 2.4" (W) x 5.0" (L)
2.2 cm (H) x 6.1 cm (W) x 12.7 cm (L)
Charger Weight 6 oz. (170 g) with battery
Charger Power Requirements One 9 volt alkaline battery
Charger Output Positive: 1250 V ± 5%
Negative: -1250 V ± 5%
Certifications UL, C-UL, CE, CB-scheme, NOM
3
Electronic Handling & Protection Division
6801 River Place Blvd.
Austin, TX 78726-9000
http://www.3M.com/ehpd
Recycled paper
40% Pre-consumer waste paper
10% Post-consumer waste paper
Litho in USA.
© 3M IPC 2000 98-0799-0473-0 (x0xx.x)JHA/
Important Notice
All statements, technical information, and recommendations related to
3M’s products are based on information believed to be reliable, but the
accuracy or completeness is not guaranteed. Before using this product,
you must evaluate it and determine if it is suitable for your intended
application. You assume all risks and liability associated with such use.
Any statements related to the product which are not contained in 3M’s
current publications, or any contrary statements contained on your
purchase order shall have no force or effect unless expressly agreed
upon, in writing, by an authorized officer of 3M.
Warranty; Limited Remedy; Limited Liability.
This product will be free from defects in material and manufacture for a
period of one (1) year from the date of purchase. 3M MAKES NO OTHER
WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. If this product is defective within the warranty period stated
above, your exclusive remedy shall be, at 3M’s option, to replace or repair
the 3M product or refund the purchase price of the 3M product. Except
where prohibited by law, 3M will not be liable for any loss or damage
arising from this 3M product, whether direct, indirect, special, incidental or
consequential regardless of the legal theory asserted.
For ordering information, technical information, product information,
you can reach us at:
Phone 1-800-328-1368
Fax 1-800-828-9329 or 1-512-984-2210
3M 718A Air Ionizer Test Kit
4