ManualsOnline posted an answer 10 years, 7 months ago

The ManualsOnline team has found the manual for this product! We hope it helps solve your problem. Get the Manual Here
5 Hi,I need to correct your mistake there its actually pilot light.If the gas valve has a thin copper wire(thermocouple) from it to the burner area and a knob with on/off/pilot positions then it has a pilot light. If not it probably is a newer furnace with a HSI (hot surface igniter) and no pilot light. Follow that wire to the pilot burner, Turn knob to pilot/hold down/light pilot with match/hold for 60 seconds and slowly release. If it goes out call a tech to replace thermocouple/clean pilot burner etc.Hope this helps