I have reset my water heater but it keeps recycling to "warm- vacation" mode. After turning it off for 5 minutes and restarting, it kicks on for 30 seconds, as if running properly, the shuts down, restarts the blower for 30 seconds and the stops. Three lights appear under Warm/vacation and A and B. I can't change the temp unless I restart. Model # PR650 XCVIT2 50gallon gas. Thanks! Tom

Asked by Tom on 07/22/2008 3  Answers

ManualsOnline posted an answer 16 years, 4 months ago

The ManualsOnline team has found the manual for this product! We hope it helps solve your problem. Get the Manual Here
0 I have the exact same issue. Did you find any resolution?
Was this answer helpful?
0 I was able to find my own solution by cleaning the thermal sensor with sand paper. NOTE: Even though it looked clean it need a couple swipes to knock off a very thin layer of combustion build up.
Was this answer helpful?

Add Your Answer