the blower wont shut off and flame wont come on. I replaced the circut board and nothing changed

Asked by larry on 11/10/2008 3  Answers

ManualsOnline posted an answer 16 years ago

The ManualsOnline team has found the manual for this product! We hope it helps solve your problem. Get the Manual Here
3 --- Normal - No call for Heat Flashing Fast --- Normal - Call for Heat Continuous ON --- Replace IFC Continuous OFF --- Check Power 2 Flashes --- System Lockout (Retries or Recycles exceeded) 3 Flashes --- Draft Pressure Error - Possible problems: a) Venting problem b) Pressure switch problem c) Inducer problem 4 Flashes --- Open Temperature Limit Circuit 5 Flashes --- Flame sensed when no flame should be present 6 Flashes --- 115 volt AC power reversed, poor grounding or system voltage too low 7 Flashes --- Gas valve circuit error 8 Flashes --- Low flame sense signal
Was this answer helpful?
0 Mine is a model Rheem Criterion RGPJ-07EAUER I reset the small switches and get all blowers running, but no gas flow or ignition. The circuit board has two led lights. One is green and blinks 3 times and pauses. The other is amber and stays off (flame). I really need to know what the 3time green flash code means???? Does anyone have a manual or list of error flash codes???
Was this answer helpful?
0 My furnace is not working all the lights are off is their a reset switch ? Or am I for a big bill,
Was this answer helpful?

Add Your Answer