the blower wont shut off and flame wont come on. I replaced the circut board and nothing changed

Asked by larry on 11/10/2008 3  Answers

ManualsOnline posted an answer 15 years, 10 months ago

The ManualsOnline team has found the manual for this product! We hope it helps solve your problem. Get the Manual Here
3 --- Normal - No call for Heat Flashing Fast --- Normal - Call for Heat Continuous ON --- Replace IFC Continuous OFF --- Check Power 2 Flashes --- System Lockout (Retries or Recycles exceeded) 3 Flashes --- Draft Pressure Error - Possible problems: a) Venting problem b) Pressure switch problem c) Inducer problem 4 Flashes --- Open Temperature Limit Circuit 5 Flashes --- Flame sensed when no flame should be present 6 Flashes --- 115 volt AC power reversed, poor grounding or system voltage too low 7 Flashes --- Gas valve circuit error 8 Flashes --- Low flame sense signal
Was this answer helpful?
0 Mine is a model Rheem Criterion RGPJ-07EAUER I reset the small switches and get all blowers running, but no gas flow or ignition. The circuit board has two led lights. One is green and blinks 3 times and pauses. The other is amber and stays off (flame). I really need to know what the 3time green flash code means???? Does anyone have a manual or list of error flash codes???
Was this answer helpful?
0 My furnace is not working all the lights are off is their a reset switch ? Or am I for a big bill,
Was this answer helpful?

Add Your Answer

Please Note: Do not submit personal information as it will be displayed online.