The burners will run for a few seconds then the flame goes out and the blower fan turns on and will run for a while blowing basically luke warm air. I thinking the wiring/circuit board is the proble. The fella who installed it for me is not around and I don't have a manual to consult or a troubleshooting guide. If anyone has a manual and some suggestions on what the problem may be I would welcome your help...it's beginning to feel a lot like winter. Thanks!!

Asked by Myles on 11/15/2008 1  Answer

ManualsOnline posted an answer 15 years, 12 months ago

The ManualsOnline team has found the manual for this product! We hope it helps solve your problem. Get the Manual Here
5 Check the circuit board. If the yellow light is flashing when the flames are on the flame sensor is dirty or bad. The flame sensor has one wire going to it and looks like a little metal rod. It is placed on the rightmost burner and measures the heat. It should be one screw to unscrew the sensor. You can try cleaning the metal rod, just scrub it with a dry toothbrush or something. The yellow light should be solid on when the flame is on. I just had this issue myself. The part is only like $25 or something.
Was this answer helpful?

Add Your Answer

Please Note: Do not submit personal information as it will be displayed online.