goodman gun-100 furnace the pilot will not lite. The inducer motor starts up and there is a constant intermittant spark from the ignitor, and there is gas going into the gas valve. Appears there's no gas coming out of the pilot gas line.

Asked by Dan on 11/14/2011 1  Answer

ManualsOnline posted an answer 13 years ago

The ManualsOnline team has found the manual for this product! We hope it helps solve your problem. Get the Manual Here
0 check for 24 volts at the gas valve on terminals pv to common, if you have 24 volts and no pilot gas then gas valve is bad, and needs to be replaced. be sure to remove pilot tubing from gas valve to make sure that the pilot assembly is not blocked with foreign matter.
Was this answer helpful?

Add Your Answer

Please Note: Do not submit personal information as it will be displayed online.