i keep getting a p error code. just wondering what's wrong with it. i've tried doing the troubleshooting steps and noting works. I get the code on start up and then i have to reset it and by the second or third time it starts.

Asked by Kim on 01/06/2009 6  Answers

ManualsOnline posted an answer 15 years, 10 months ago

The ManualsOnline team has found the manual for this product! We hope it helps solve your problem. Get the Manual Here
5 p code is press. switch. open left access door & locate hose on top of the exhaust blower. disconnect hose & blow through it to clear obstruction. re-install hose. this should clear p code. hope this helped. cheers, Tom
Was this answer helpful?
2 Your pellet stove is not venting properly on start up. There is a sensor that checks the pressure in your vent. If there is negative pressure it shuts off. After two or three times the fan has started pushing against that pressure and gets a bit of a draft going, the sensor senses it and continues starting up.
Was this answer helpful?
0 How to reset H-1 code after 3 trys.
Was this answer helpful?
0 I had the same problem, I cleaned the blower fan, cleared the pressure switch air tube, cleaned the pressure switch nozzle, but nothing worked. I then thought "if it has to do with venting and exhausting, perhaps the chimney is the issue". Sure enough, the chimney was clogged. After cleaning the chimney, the stove runs fine now.
Was this answer helpful?
0 where is the reset botton
Was this answer helpful?