I have a dayton hanging furnace 3E403B. The pilot lights and stays lit, the fan kicks on when the thermostat calls for heat, but the main burners won't ignite.

Asked by tonytollis2 on 05/08/2020 1  Answer

ManualsOnline posted an answer 4 years, 7 months ago

The ManualsOnline team has found the manual for this product! We hope it helps solve your problem. Get the Manual Here
0 I have the 3E402D and had the same issue. Turn the power off, you don't have to shut off the gas, and there is a "Blocked Vent Shutoff (Spill) Switch" button that needed to be reset. Mine was located on the upper left side near the front of the unit, behind a little pivoting metal "door". Sticking my finger through that "door" access, feel for a button and press it in to reset. With mine, after maybe 15-30 seconds, I'd hear a click from the unit. Then, I turn the power back on and the burners will ignite (if T-stat calls for heat on).
Was this answer helpful?

Add Your Answer