clean all filter. hydrogenarator reading 1.7volts it has a red&black wire connection.red light indicating low water pressure have checked all water lines no obstructions still will not light burners

Asked by tony on 12/25/2009 1  Answer

ManualsOnline posted an answer 14 years, 11 months ago

The ManualsOnline team has found the manual for this product! We hope it helps solve your problem. Get the Manual Here
1 Turn on the hot tap full to ensure water delivery is happening, at this point check the hydropower turbine for voltage. It must have a minimun of 3.5 l per min to fire up but look for about 7.5. Ensure water pressure is turning turbine, if not remove, clean or replace. Use a lubricant suitable for plastics or rubber. If all is well then i would sugest the low water pressure switch is at fault illuminating the light. Change switch. Good luck and keep me informed