My armstrong gas furnace model GUJ075D10-2b will not light the furnace blower starts and makes a clocking sound but the burner will not light.

Asked by Joe on 11/06/2013 1  Answer

ManualsOnline posted an answer 10 years, 6 months ago

The ManualsOnline team has found the manual for this product! We hope it helps solve your problem. Get the Manual Here
5 When the furnace is attempting to light look for a bright orange glow coming from inside the furnace it should be visible thru the cover panel louvres. If you don't see this, the igniter may have gone out; or possibly obstructed exhaust vent. If u see the glow and the gas will not remain lit, it's most likely a dirty flame sensor.