SEALED COMBUSTION
DOWNFLOW GAS FURNACE
MODELS: DGAA, DGAH, DGPA, AND DGPH
For Installation In:
1, Manufactured (Mobile) Homes
2. RecreationaIVehicles & Park Models
3. Modular Homes & Buildings
IMPORTANT - Only individuals having proven expedence with this
type ofequipment shouldattempt to performset-up.
Proper furnace set-up and adjustment is the responsibility of the
retailer/homeowner and is not covered under warranty.
FURNACE START-UP CHECK LIST
Has roof jack crownbeen correctlyinstalled?
Has furnace gas valve and burner orificebeen correctlycon-
vetted for Propane. gaswhere applicable?
Has furnace gas valve been de-rated foraltitudesabove 2000
feet where applicable?
Is gas lineoutletpressure properlyset for fuel type? (naturalgas
is 3.5" W.C.; Propane is 10"W.C.)
Is cross-overduct installed per homebuilderand UPG installa-
tion instructions?
Has furnace been operated througha complete heating cycle?
Has the pilotflame been adjusted properly? (DGPH and DGPA
Models)
035-16328-002 Rav. C (0902)