Windsor SC20 Vacuum Cleaner User Manual


 
MACHINE TROUBLESHOOTING
SABER (SC) 86038350 01/29/07
4-10
PROBLEM CAUSE SOLUTION
Little or no solution flow to the
floor
Solution tank empty Fill solution tank
Solution flow turned off or
set too low
Turn on or increase flow
setting
Solution strainer plugged Clean solution strainer
Solution hoses obstructed Clear obstruction from
hose
Solution solenoid valve
obstructed or stuck
(traction model only)
Clean or replace
No power to machine Battery disconnected Check all battery cable
connections
Emergency shut-off
activated (traction model
only)
Reset
Battery connections
corroded
Clean connections
Faulty main contactor Replace contactor
Faulty power switch Replace switch
Little or no propel (traction model Low battery charge Charge batteries
only) Machine turned on with
directional control button(s)
not in neutral
Allow control button to
return to neutral. Restart
Controller overheated Allow cool down period
Loose connection Check motor wires and
connection