Williams 1403611 Furnace User Manual


 
Safety Rules
WARNING
READ THESE RULES AND THE INSTRUCTIONS
CAREFULLY. FAILURE TO FOLLOW THESE
RULES AND INSTRUCTIONS COULD CAUSE A
MALFUNCTION OFTHE FURNACE. THIS COULD
RESULT tN DEATH, SERIOUS BODILY INJURY,
AND/OR PROPERTY DAMAGE.
umn. The maximum inlet gas supply pressure is 13"
water column.
ANY SAFETY SCREEN, GUARD OR PARTS RE-
MOVED FOR SERVICING AN APPLIANCE MUST BE
REPLACED PRIOR TO OPERATING THE AP-
PLIANCE TO AVOID PROPERTY DAMAGE, BODILY
INJURY OR DEATH.
INSTALLATION MUST CONFORM TO LOCAL CODES. IN
THE ABSENCE OF LOCAL CODES, INSTALLATIONMUST
CONFORM WITH THE NATIONAL FUEL GAS CODE, ANSI
Z223.1. THE APPLIANCE, WHEN INSTALLED, MUST BE
ELECTRICALLY CONNECTED AND GROUNDED IN
ACCORDANCE WITH LOCAL CODES OR, IN THE
ABSENCE OF LOCAL CODES, WITH THE CURRENT
NATIONAL ELECTRICAL CODE ANSI/NFPA NO. 70.
IN CANADA
1. INSTALLATION MUST CONFORM TO LOCAL
CODES OR, IN THE ABSENCE OF LOCAL
CODES, THE CURRENT CAN/CGA B149 IN-
STALLATION CODE.
2. THE APPLIANCE, WHEN INSTALLED, MUST BE
ELECTRICALLY CONNECTED AND GROUND-
ED IN ACCORDANCE WITH LOCAL CODES OR,
IN THE ABSENCE OF LOCAL CODES, WITH
THE CURRENT CSA C22.1 CANADIAN ELEC-
TRICAL CODE.
3. FIELD CONVERSIONS FOR HIGH ALTITUDE
ARE NOT PERMITTED IN CANADA.
4. REFERENCE IS MADE IN THIS MANUAL
REGARDING GAS TYPE AS L.RG. BE ADVISED
THAT L.RG. IS NOT AVAILABLE IN CANADA,
REFER TO PROPANE/L.R GAS.
,
9.
10.
11.
12.
13.
14.
15.
INSTALL the furnace vent directly to the outdoors, so
that harmful gasses will not collect inside the building.
Follow the venting instructions for your type installa-
tion exactly. Use only the type and size of vent pipe
and fittings specified.
BE SURE to provide for adequate combustion and
ventilation air. See page 7. The flow of this air to the
furnace must not be blocked.
NEVER vent flue gases into another room, a fireplace
or any space inside a building. This could cause pro-
perry damage, bodily injury or death.
NEVER test for gas leaks with an open flame. Use
soap sudsto check all gas connections. This willavoid
the possibility of fire or explosion.
ALLOW furnace to cool before servicing. Always shut
off electricity and gas to furnace when working on it.
This will prevent any electrical shocks or burns.
DUE TO HIGH TEMPERATURES, locate the furnace
out of traffic and away from furniture and draperies.
ALERT children and adults to the hazards of high sur-
face temperature and to keep away to avoid burns or
clothing ignition.
CAREFULLY supervise young children when they are
in the same room with the furnace.
1,
2.
3.
4.
5.
6,
I
USE ONLY MANUFACTURER'S REPLACEMENT
PARTS. USE OF ANY OTHER PARTS COULD CAUSE
INJURY OR DEATH.
DO NOT install this furnace in an alcove.
DO NOT install these furnaces in a travel trailer,
recreational vehicle or mobile home.
MAINTAIN all clearances specified in section
"Locating Wall Furnace and Thermostat" and "Vent
Installation."
BE SURE furnace isfor type ofgas to be used. Check
the rating plate by the gas valve in the lower cabinet.
Do not change it to use other gases. Unsafe opera-
tion could result and could cause bodily injury and
death.
For Natural gas, the minimum inlet gas supply
pressure for the purposeof input adjustment is5" col-
umn. The maximum inlet gas supply pressure is 7"
water column.
For L.R gas, the minimum inlet gas supply pressure
for the purpose of input adjustment is 11" water col-
16.
17.
18.
19.
20.
DO NOT place clothing or other flammable material
on or near furnace.
INSTALLATION and REPAIR mustbe done by a quali-
fied service person. The appliance should be inspected
before use and at least annually by a professional serv-
ice person. More frequent cleaning may be required
due to excessive lint from carpeting, bedding material,
etc. It is imperative that control ,compartments, burners
and circulating air passages be kept clean.
BEFORE INSTALLING: Toavoid electrical shock, turn
off electrical circuits that pass through the wall where
you are going to install the furnace.
BE AWARE of good safety practices by wearing per-
sonal protective equipment such as gloves and safe-
ty glasses to avoidbeing injured bysharp metal edges
inor around furnace and while cutting or drilling holes
in wood and or sheet metal,
CAUTION: Label all wires prior to disconnection when
servicing controls. Wiring errors can cause improper
and dangerous operation. Verify proper operation after
servicing.
WARNING
DO NOT USE THIS HEATER IF ANY PART HAS BEEN UNDER WATER. IMMEDIATELY CALL A QUALIFIED
SERVICE TECHNICIAN TO INSPECT THE HEATER AND TO REPLACE ANY PART OF THE CONTROL SYSTEM
AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER.
4,.,,-4 m