Weil-McLain PLUS-E017-A/1206 Water Heater User Manual


 
6
Part Number PLUS-E017-A/1206
PLUS LINE
Indirect-Fired Water Heaters – Series 3
Codes
Installation must conform with instructions in this manual and, where applicable:
local, state, provincial, and national codes, laws, regulations and ordinances.
in Canada — B149.1 or B149.2 Installation Code.
PLUS water heaters are exempt from ASME Section VIII, Division 1 Code construction per
Interpretation VIII-1-86-136. Check with local codes for applicability.
Where recommendations in this manual differ from local or national codes, local or national
codes take precedence.
Recommended
clearances
Installation location must provide adequate clearances for servicing and proper operation of
the water heater.
GOLD Plus 30/40/60/80 or Plus 40/60/80 (see Figure 1)
Zero clearance is permissible to either side of water heater, but Instruction label or other
labels may be hidden.
Top (vertical) clearance is 12” minimum.
Refer to boiler manual for boiler clearances.
PLUS 100/110/119 (see Figure 1)
Zero clearance is permissible to either side of the water heater, but Instruction label or
other labels may be hidden.
Top (vertical) clearance is 12” minimum.
Refer to boiler manual for boiler clearances.
Location
This water heater is not intended for outdoor installation.
Select a convenient location for water heater, based on domestic and boiler piping hook-ups.
Keeping the distance between boiler and water heater short will:
reduce piping heat loss.
provide minimum friction loss.
Install water heater so if tank or any connections should leak, the water flow will not cause
damage to area near water heater, or to lower floors of structure. When such locations cannot
be avoided, install a suitable drain pan under water heater. Drain pans are available at your
local plumbing supply store.
This product is designed for vertical installation only.
Figure 1
Clearance recommendations
A1 Pre-installation