Wayne 330102-001 Septic System User Manual


 
© 2009 Wayne Water Systems
330102-001 2/09
Effluent
Pump
Operating Instructions and Parts Manual Model EFL33
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Description
An effluent system consists of a pump,
control switch and a basin. The system
is generally controlled by a float switch
with a plug-in plug which accepts the
pump plug and in turn plugs into a 115
volt outlet.
The float switch is a wide angle
differential switch that rises with
the liquid level and turns the pump
on. As the liquid level decreases, the
float lowers and turns the pump
off. This pump is intended for use in
domestic sump or effluent lift stations.
It is suitable for pumping effluent,
wastewater, ground water and other
nonexplosive, noncorrosive liquids with
up to 3/4 inch solids.
Effluent pump will
not pump raw
sewage or any substance exceeding
3/4 inch size.
For parts, product & service information
visit www.waynepumps.com
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
Specifications
Power supply requirements .............. 115V, 60 hz
Circuit requirements .......................... 15 amps (min)
Motor duty ......................................... Intermittent
Motor ................................................. 115V, 1 Phase, 1725 RPM
Horsepower ....................................... 1/3
Motor full load .................................. 11 amps
Liquid temperature range ................. 40º F to 120º F
Max. operating position .................... 45º from vertical
Dimensions ......................................... 13-1/2 inch x 11 inch
Intake ................................................. 2 inch
Discharge ............................................ 2 inch NPT female, 3 inch
NPT male
Cut-in level (factory set) ....................18 inch
Cut-out level (factory set) ................. 10 inch
Differential ......................................... 8 inch
Switch ................................................. 90º wide angle
mechanical tether switch
Power cord ......................................... 16 gauge 3 conductor
w/plug
Construction
Motor body material ............Cold rolled steel
Motor housing ......................Glass reinforced
polypropylene
Volute ....................................Glass reinforced ABS
Impeller .................................Glass reinforced PBT
Seal plate ..............................Cast Iron
Shaft seal ...............................End faced mechanical
Performance
GALLONS PER HOUR AT TOTAL HEAD IN FEET
Model 10 15 200
EFL33 3600 1300 0
Unpacking
Inspect this unit before it is used.
Occasionally, products are damaged
during shipment. If the pump or
components are damaged, return
the unit to the place of purchase for
replacement. Failure to do so could
result in serious injury or death.
Safety Guidelines
This manual contains information
that is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols.
Danger indicates
an imminently
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
Warning indicates
a potentially
hazardous situation which, if not
avoided, COULD result in death or
serious injury.
Caution indicates
a potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates
important
information, that if not followed, may
cause damage to equipment.
General Safety Information
CALIFORNIA PROPOSITION 65
This product or its
power cord contains
chemicals known to the State of
California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.