Watlow Electric FREEZE-SAFE Electric Heater User Manual


 
FREEZE-SAFE
Classified Location
Flexible Heated Mats
for Low Temperature
Applications
Based on its patented THERMOPOLYMER
®
technology,
Watlow has embedded a safe, low watt density heating
element into a thermoplastic elastomer mat.
Watlow’s FREEZE-SAFE hazardous location Thermo Plastic
Elastomer (TPE) heated mats are custom designed for
your application in sizes or shapes up to 20 x 25 inch
(508 x 635 mm). Consult the factory for larger sizes.
FREEZE-SAFE heated mats are designed for use in
classified locations. (Class 1, Div. II, Group A, B, C, D).
Class 1, Div. II are locations where explosive vapor conditions
could exist in the event of abnormal operation, an accident,
or component failure. Flammable gases and liquid groups
(such as acetylene, hydrogen, ethylene, gasoline and
propane)
are included in this classification. Refer to articles
500 through 505 of the National Electric Code for more
information on the use of electrical devices in classified
locations.
The hazardous location heated mat can be used in a variety
of ways. These flexible panels provide spot supplemental
heat-tracing while simplifying installation and maintenance.
Nearly any curved 3-D shape can be wrapped with a Watlow
FREEZE-SAFE flexible heated mat. Multiple heaters can be
used to cover the entire surface.
FREEZE-SAFE
©
2007 Watlow Electric Manufacturing Company
Features and Benefits
THERMOPOLYMER heated mats are free from seams
and joints
Safe for use in classified and outdoor environments
Mats are hermetically sealed against liquids and
explosive vapors
Prevents nuisance faults
Prevents heater damage due to dangerous leaks
Excellent resistance to UV, non-aromatic fuels, abrasion
and tearing
Provides toughness and durability
Reduced maintenance cost
Allows for easy removal and installation for valve and
pipeline maintenance
Long heater life
Low watt density
Made to fit unusual shapes
Custom designed and molded by the factory to
accommodate curved or other odd shapes
Performance Capabilities
Watt densities from 0.1 to 1 watt per square inch
Operating wattage from 5 to 350W
Operating voltages from 12 to 48V, 120 or 240V
Ambient operating temperatures from -40 to 24°C
(-40 to 75
°
F)
Maximum heater surface temperature 50°C (122°F)
Supplied with 18 gauge, three conductor STOW cord,
maximum length is 18 inches
UL
®
515 listed
T
ested to meet a 5V
A flammability rating
Applications
Electrical box heating
Liquid line, cylinder, tube and pipe freeze protection
P
etrochemical refining
Power generation water injection
Warming applications
Low temperature processing
Availability
Hazardous location heater panels are custom designed for
your application. Consult factory for details and pricing.
2101 Pennsylvania Drive
Columbia, Missouri 65202 USA
Phone: +1 (573) 474-9402
FAX: +1 (573) 474-5859
Internet: www.watlow.com
E-mail: info@watlow.com
COL-FRZS-0407
UL
®
is a registered trademark of Underwriter’s Laboratories, Inc.
To be automatically connected to the nearest North American Technical and Sales Office call:
1-800-WATLOW2
International Technical and Sales Offices: Australia, +61-3-9335-6449 • China, +86-21-3950-9510 • France, +33 (0) 3073-2425 •
Germany, +49 (0) 7253-9400-0 • Italy, +39 (0) 2 458-8841 • Japan, +81-3-3518-6630 • Korea, +82-2-575-9804 • Malaysia, +60-3-7980-7741 •
Mexico, +52 (442) 217-6235 • Shanghai, +86-21-3950-9504 • Singapore, +65-6773-9469 • Spain, +34 91 675 1292 • Sweden, +46 35-27-11-66 •
Taiwan, +886-7-288-5168 • United Kingdom, +44 (0) 115-964-0777