Tyco QuickStatTM Thermostat User Manual


 
QuickStat
Thermostat
Installation & Operation Manual
General Information
Use of this Manual
This manual covers the installation and operation of the Raychem
®
QuickStat
thermostat and must be used with the following document:
QuickNet
System Installation Manual
(H57704)
Important:
For the Tyco Thermal Controls warranty and agency
approvals to apply, the instructions included in this manual and product
packages must be followed.
Features
QuickStat is an electronic thermostat that must be used with the
Raychem QuickNet floor warming mats.
QuickStat provides the following features:
Includes an integrated Class A, Ground-fault Circuit Interrupter (GFCI).
Operates at 120/240 V 50/60 Hz.
Switches on your heating system at predetermined times on different
days of the week.
Offers 4 periods (called events) each day that you can set at different
temperatures.
Comes with a preprogrammed schedule that is suitable for most
installations. However, you can customize this program any time you
wish.
Allows you to reset the thermostat to factory settings.
Changes the start time of a heating period automatically so that the
desired temperature is reached at the time that you set.
Controls the temperature of the floor through a temperature sensor
that is placed in the floor construction.
Specifications
Approvals
Technical Data
Supply Voltage 120/240 V ±15%, 50/60 Hz
Maximum switching current 16 A
Wiring 12 AWG to 22 AWG
GFCI Class A (5 mA trip level)
Temperature control range 40 to 104˚F (5 to 40°C)
Ambient temperature range
Thermostat 32 to 104˚F (0 to 40°C)
GFCI –31 to 149˚F (–35 to 65°C)
C US
LISTED
2D03
E157297
A
B
C
Kit contents
A 1 QuickStat thermostat
B 2 Mounting screws
C 1 Floor temperature sensor 10 ft (3m)