Trane PRC001-EN Air Conditioner User Manual


 
7RT-PRC001-EN
Black Epoxy Coated Condenser Coil
The coil provides corrosion protection to
condenser coils for seacoast application.
Cabinet Integrity
For added water integrity, Voyager has a
raised 1
1
/
8
" lip around the supply and
return of the downflow units to prevent
water from blowing into the ductwork.
Clogged Filter/Fan Failure Switch
A dedicated differential pressure switch is
available to achieve active fan failure
indication and/or clogged filter indication.
CO
2
Sensing
The CO
2
sensor has the ability to monitor
space occupancy levels within the
building by measuring the parts per
million of CO
2
(Carbon Dioxide) in the air.
As the CO
2
levels increase, the outside air
damper modulates to meet the CO
2
space ventilation requirements. The CO
2
sensor kit is available as a field installed
accessory.
Colored And Numbered Wiring
Save time and money tracing wires and
diagnosing the unit.
Compressors
Voyager contains the best compressor
technology available to achieve the
highest possible performance. Dual
compressors are outstanding for
humidity control, light load cooling
conditions and system back-up
applications. Dual compressors are
available on all models.
Refrigerant Circuits
All Voyager 12½-25 ton units shall have
crankcase heaters, low and high pressure
controls as standard.
Condenser Coil
Voyager boasts a
patent-pending
1+1+1 condenser
coil, permanently
gapped for easy
cleaning.
Outstanding Standard and
Optional Components
Dehumidification (Hot Gas Reheat)
Option
This option allows for increased outdoor
air ventilation. It
reduces humidity
levels while
increasing
comfort level in
the air space.
Cooling can
operate without a
demand for
dehumidification.
The hot gas reheat
coil is designed to
deliver maximum
reheat
temperature.
Digital Display Zone Sensor
The Digital LCD (Liquid Crystal Display)
zone sensor has the look and functionality
of standard zone sensors. This sensor
should be utilized with ReliaTel™ controls.
Discharge Air Sensing Kit
Provides true discharge air sensing in
heating models. The kit is functional only
with the ReliaTel Options Module.
Downflow And Horizontal Economizers
The economizers come with three control
options — dry bulb is standard, enthalpy
and differential enthalpy are optional.
Dual Thermistor Remote Zone Sensor
This sensor will reduce the total number
of remote sensors to obtain space
temperature averaging. This sensor
should be utilized with ReliaTel controls.
Factory Built Roof Curbs
Available for downflow units. Only two
roof curbs for the entire Voyager line
simplifies curb selection.
Fresh Air
0 - 25% manual or 0 -
50% motorized outside
air hoods are available.
Low Static Drive
Accessory
This option shall allow
the standard motor to
operate at lower static
performance. (See Fan
Performance tables).
High Static Drive Accessory
Available on many models, this high
static drive accessory extends the
capability of the standard motor. Avoid
expensive motors and operating costs by
installing this optimized sheave
accessory.
Hinged Access Doors
These doors permit easy access to the
filter, fan/heat, and compressor/control
sections. They reduce the potential roof
damage from screws or sharp access
door corners.
LonTalk® Communications Interface
The LonTalk communications interface
allows the unit to communicate as a
Tracer™LCI-V device or directly with
generic LonTalk Network Building
Automation System Controls.
Power Exhaust Option
This option is available on downflow units
and provides exhaust of the return air,
when using a downflow economizer, to
maintain proper building pressurization.
Great for relieving most building
overpressurization problems.
Quick-Access Panels
Remove three or fewer screws for
access to the standardized internal
components and wiring.
Quick-Adjust Idler Arm
With the Quick-Adjust Idler Arm, the belt
and sheaves can be quickly adjusted
without moving the mounted fan motor.
The result is a major savings in time and
money.
Features and